Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to Instruction
Warning:
Manual
Explosive Material
Read and understand the general safety and operating instructions before use. The following information is intended to help
you keep the product in top working order.
NOTE – The battery in this unit is a consumable item and its ability to accept charge will reduce over time. We will warrant it
against mechanical and electrical defect for a period of one year - this does not cover fair wear and tear.
If the battery is not properly charged before first use, or regularly conditioned, its capacity will diminish. Under these circumstances we
will not replace the battery even if it is less than one year old.
The Reverse Charging Protection Diode, fitted in the positive lead, is a consumable part that is damaged by failure to adhere to the
duty cycle instructions.
You can help prolong the life cycle of the battery by following a few simple guidelines:
Plug in your new RoadStart to the mains transformer and make an INITIAL charge lasting 72 hours.
Ensure the unit is fully charged before storage.
DO NOT leave the RoadStart for longer than 2 months without putting it on charge.
DO NOT attempt to start a vehicle when the RoadStart battery voltage is reduced to less than 7V.
DO NOT drop or handle the RoadStart roughly – this will break or disconnect the battery terminals rendering the battery useless and
the warranty void.
DO NOT use any other charger, other than the one supplied, to recharge the battery.
DO NOT obstruct the ventilation grilles and protect against water ingress - these RoadStart units are fitted with ventilation grilles to
help disperse any gases produced during the charging procedure.
1. SAFETY
IMPORTANT: To reduce the risk of a battery explosion, follow these instructions and those published by the battery manufacturer and the
manufacturer of any equipment you intend to use in the vicinity of the battery. Remember to review warning marks on all products and on engines.
Modern vehicles contain extensive electronic systems.
You are required to check with the vehicle manufacturer, for any specific instructions regarding the use of this type of equipment on each
vehicle. No liability will be accepted for damage / injury, where this product is not used in accordance with all instructions.
1.1.
PERSONAL PRECAUTIONS
Ensure there is another person within hearing range, or close enough to come to your aid should a problem arise, when working near
9
a lead-acid battery.
Have fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
9
Wear safety eye protection and protective clothing. Avoid touching eyes while working with a battery.
9
Wash immediately with soap and water if battery acid contacts skin or clothing. If acid enters eye, flush eye immediately with cool, clean
9
running water for at least 15 minutes and seek immediate medical attention.
Remove personal metallic items such as rings, bracelets, necklaces and watches. A lead-acid battery can produce a short-circuit current
9
high enough to weld a ring or the like to metal, which may cause severe burns.
9
1.2.
IMPORTANT SAFETY INSTRUCTIONS
Familiarise yourself with the applications, limitations and potential hazards of the RoadStart.
9
Keep the unit in good working order and condition. Replace damaged parts immediately.
9
Use only recommended parts. To use unapproved parts may be dangerous and will invalidate your warranty.
9
The RoadStart must only be opened and checked by qualified service personnel. DO NOT disassemble the unit for any reason.
9
Keep children and unauthorised persons away from the work area.
9
Keep work area clean and tidy and free from unrelated materials. Ensure that there is adequate lighting.
9
If the RoadStart receives a sharp knock or blow, it must be checked by a qualified service agent before being used.
9
When not in use re-charge every two months.
9
8 8 DO NOT touch positive and negative clamps together as this could cause an explosion.
8 8
8 8 DO NOT smoke or allow a spark, or flame in the vicinity of the battery or engine.
8 8
8 8 DO NOT drop any metal item onto the battery as it may spark or short circuit the battery, which could cause an explosion.
8 8
8 8 DO NOT use RoadStart to recharge dry cell batteries that are commonly used with home appliances. These batteries may explode and
8 8
cause personal injury and damage to property.
8 8 DO NOT charge or boost a frozen battery.
8 8
© Jack Sealey Limited
INSTRUcTIoNS FoR:
ROADSTART UNIT
ModEL No:
Use in Well
Keep Away From
Ventilated Areas
Sources of Ignition;
Battery could
IMPORTANT WARRANTY INFORMATION: KEEP YOUR ROADSTART HEALTHY
Original Language Version
RS125.V4
Wear
Eye
Protection
Explode
Wear
Protective
Gloves
RS125.V4| Issue:1 10/01/17

Advertisement

loading

Summary of Contents for Sealey RS125.V4

  • Page 1 RS125.V4 ModEL No: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Rcd (Residual current device) is used with all electrical products. It is particularly important to use an Rcd with portable products that plug into an electrical supply not protected by an RccB. If in doubt consult a qualified electrician. You can obtain a Residual current device through your Sealey dealer. You must read and understand instructions concerning electrical safety. 1.3.1.
  • Page 3 5.12.2. Used with an inverter, the RoadStart unit can operate equipment usually powered by either 110VAc or 230VAc. 5.12.3. The Sealey catalogue contains a range of suitable inverters. NOTE: The inverter power draw must not exceed 300 Watts. 5.13. The number of times that the RoadStart can be used between charges depends on a number of factors, for instance: the type and size of engine being started, the state of charge and the ambient temperature will all affect the endurance of the unit.
  • Page 4 Reverse charging device inoperative. Return to stockist. Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. Environmental Protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.