10.5 Fast Access to Parameters with Button Combinations
VFC 3210 provides fast access to parameters within a parameter group with
'<Func> + <▲>' or '<Func> + <▼>' combinations. This function is only valid for the
tens digit of the function code index '□□.x□'.
Pressing '<Func> + <▲>' once: '□□.x□' is changed to '□□.x+1□'
●
Pressing '<Func> + <▼>' once: '□□.x□' is changed to '□□.x-1□'
●
Example: The frequency converter is now displaying 'E0.07' after setting with
<Func>, <Set>, <▲> and <▼> buttons.
If 'E0.17' needs to be displayed based on 'E0.07', <▲> button has to be pressed
for 10 times in the traditional way as described in the above figure. However,
with button combination function, it is only necessary to press '<Func> + <▲>'
buttons once.
The parameter fast access function is only available when [b0.00]
●
= 0, 1, or 2, unavailable with parameters in groups '-PF-' or '-EP-'
Press <Func> button and do not release it until <▲> or <▼> button
●
has been pressed.
Press <▲> or <▼> button within 2 s if <Func> button is pressed.
●
If the index of parameters is not continuous in a specific parame-
●
ter group, the adjacent parameter will be accessed. For example,
the display of 'E0.01' should be changed to 'E0.11' with '<Func> +
<▲>' button function. However, parameter E0.11 is unavailable in
group E. While the adjacent parameter is E0.15. In this case,
'E0.15' is accessed and displayed.