14. System Test 1: Assure there is no water dripping from the seal
compression nut (7). If water is visible, STOP and tighten the
compression nut (7) using a pair of channel lock pliers to a maximum
of 1/4 turn. If that does not fix the leak, then repeat quartz tube
maintenance process from step 1 through step 13. Make sure there
is no water leaking before proceeding to step 15.
15. System Test 2: Reconnect the CLEARRAY unit to the controller.
Turn breaker back ON. Turn on the pump to circulate the water
through the CLEARRAY System. Wait for 5 minutes and assure no
water is dripping. If water is visible, STOP, fix the leak by repeating
quartz tube maintenance process from step 1 through step 14. Make
sure there is no water visible and turn the pump and breaker
OFF and disconnect the CLEARRAY unit to the controller
BEFORE proceeding to step 16.
16. Reconnect the bulb socket (5) to the new UV bulb (4) make sure you
use the latex glove provided when handling the UV bulb.
Align pins on UV bulb (4) to the receptacle holes on the bulb socket
Note:
(5) before inserting the pins completely into socket holes. Failure to do so
will damage the UV bulb.
WARNING:
YOUR BARE HAND. Oil on your skin will cause hot spot on
!
the UV bulb and shorten the life of your UV bulb. Use the
provided latex glove to handle the UV bulb.
17. Slide the new UV bulb (4) back inside the quartz tube, Figure 3.
18. Reinstall the black bulb boot (8) back over the quartz seal compression
nut (7).
19. Reinstall the enclosure cover (10) with gasket (9) and secure with the
screws.
20. Reconnect the CLEARRAY System to the controller and turn on the
power to the spa.
21. Properly dispose of the old UV bulb.
WARNING:
!
which contains mercury. Dispose of the bulb in accordance
with disposal laws. See www.lamprecycle.org.
22. Once power is activated you can check the ballast
(12), Figure 7, to see if the CLEARRAY System is
functioning. A solid green light indicates that the
CLEARRAY System is being provided power and
should always be on. A solid red light indicates that
UV bulb is activated.
Page 48
DO NOT TOUCH THE NEW UV BULB WITH
This CLEARRAY System includes a UV bulb,
Indicator
Lights