Unfoldable type of transmission arm
A - Minimum space between the inner fi xture and the shutter
B - Bay width (min./max.)
One leaf, without VLR01xx batteries
One leaf, with VLR01xx+VLR05 batteries
Two leaves, without VLR02 batteries
Two leaves with VLR02+VLR05 batteries
F - Width of internal panel (min./max.)
The angle
must always exceed 90°; install a simple strike plate
For this application, fi t a corner protection
GENERAL INSTRUCTIONS FOR INSTALLING
⚠ Installation must be carried out by expert qualified personnel and in full compliance with the regulations in force.

Preliminary checks

Check that the operator fixing point is protected from possible knocks, and that the fixing surface is solid. Also check that
appropriate screws, plugs, etc. are used to fix the panel;
Set up suitable conduits and tubes to safely run the electrical cables through and to protect them from mechanical damage.
Remove the shutter opening stops and replace them with strike plates.
Make sure the angles between the two leaves always exceeds 90°.
Tools and materials
Make sure you have all the tools and materials you will need for installing in total
safety and in compliance with applicable regulations. The figure shows some of the
equipment installers will need.
Cable types and minimum thicknesses
Connection
Power supply to control panel 230 V
Accessories powered at 24 V
Command and safety device
Home & building automation connections
☞ If the cable lengths differ from that specified in the table, then you must determine the cable diameter based on the actual
power draw from the connected devices and according to the CEI EN 60204-1 standard.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual
power draw and distances. For connecting products that are not contemplated in this manual, see the literature accompanying
said products
One or two-leaved jointed double-paneled shutter
for the arm.
Cable type
FROR CEI 20-22
CEI EN 50267-2-1
CAT5 - U/UTP - AWG24
VLR08
130
500 / 1050
750 / 1050
820 / 2100
970 / 2100
140 / 170
for this.
Cable length
1 < 10 m
10 < 20 m
2
3G x 1.5 mm
3G x 2.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
2 x 0.5 mm
2
2 x 0.5 mm
max 1200 m
VLR09
160
500 / 1050
750 / 1050
900 / 2100
970 / 2100
170 / 240
20 < 30 m
2
2
3G x 4 mm
2
2
2 x 1 mm
2
2 x 0.5 mm
2