2.2 Outdoor Unit Specifications
Cooling
Operation Range
Heating
(Outdoor Tempera-
Domestic Hot
ture)
Water
Type
Model
Diplacement
Compressor
Capacity
Motor Type
Motor Output
Type
GWP
(Global Warming Potential)
Precharged Amount
Refrigerant
t-CO2 eq.
Chargeless-Pipe Length
Additional Charging Volume
Control
Type
Refrigerant Oil
Charged Volume
Quantity
Heat Exchanger
Specifications
Type
Fan
Air Flow Rate
Type
Fan Motor
Output
Sound Power Level
Heating
Liquid
Piping Connections
Gas
Piping Length
Piping Level
Outdoor Unit ~
Difference
Indoor Unit
Unit
Dimensions
Packed Unit
Unit
Weight
Packed Unit
Electrical Specification
Power Supply
Cooling
Maximum Running
Current
Heating
Power Supply Cable
Wiring Connections
(Included Earth)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And "Electric characteristics" chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Anechoic chamber. Therefore, these values depend on the ambient conditions and values are normally higher
in actual operation.
4. Performances are based on the following conditions :
• Cooling : Inlet/Outlet Water Temp. 23°C/18°C, Outdoor Air Temp. 35°CDB / 24°CWB
• Heating : Inlet/Outlet Water Temp. 30°C/35°C, Outdoor Air Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
5. This product contains Fluorinated greenhouse gases.
6
Outdoor Units
Min. ~ Max.
Min. ~ Max.
Min. ~ Max.
Model x No.
cm³/Rev.
Rated
cc x No.
Row
Column
Fins per Inch
Rated
m³/min x No.
Rated
Type
Outer Dia.
mm(inch)
Type
Outer Dia.
mm(inch)
Standard
Max.
Max.
W x H x D
W x H x D
No. x mm²
AHUW056A3 [HU051 U43]
°C DB
5 ~ 48
°C DB
-20 ~ 35
°C DB
-
-
Hermetic Motor
GJT240MAA x 1
24
kW
7.41
-
BLDC
W x No.
2,137 x 1
-
R410A
-
2,087.5
g
1,800
-
3.76
m
7.5
g/m
40
-
Electronic Expansion Valve
-
FVC68D
570 x 1
EA
1
EA
2
EA
38
EA
14
-
Propeller
58 x 1
-
BLDC
W x No.
124 x 1
dB(A)
65
-
Flare
Ø 9.52 (3/8)
-
Flare
Ø 15.88 (5/8)
m
7.5
m
50
m
30
mm
950 x 834 x 330
mm
1,065 x 918 x 461
kg
59.0
kg
65.0
AHUW056A3 [HU051 U43]
V, Ø, Hz
220-240 / 1 / 50
A
19.0
A
19.0
3 x 4.0 (H07RN-F)
Outdoor unit
AHUW076A3 [HU071 U43]
5 ~ 48
-20 ~ 35
-
Hermetic Motor
GJT240MAA x 1
24
7.41
BLDC
2,137 x 1
R410A
2,087.5
1,800
3.76
7.5
40
Electronic Expansion Valve
FVC68D
570 x 1
1
2
38
14
Propeller
58 x 1
BLDC
124 x 1
65
Flare
Ø 9.52 (3/8)
Flare
Ø 15.88 (5/8)
7.5
50
30
950 x 834 x 330
1,065 x 918 x 461
59.0
65.0
AHUW076A3 [HU071 U43]
220-240 / 1 / 50
19.0
19.0
3 x 4.0 (H07RN-F)