LG Therma V AHUW056A3 Engineering Product Data Book page 69

Air-to-water heat pump/split type r410a/50hz, total hvac solution provider
Hide thumbs Also See for Therma V AHUW056A3:
Table of Contents

Advertisement

THERMA V
Split Type
2. Specifications
2.1 Nominal Capacity and Power Input
Combination with Hydro Box type
Outdoor Unit
Model Names
Indoor Unit
Cooling
Capacity
(Rated)
Heating
Cooling
Power Input
(Rated)
Heating
EER
Cooling
COP
Heating
Prated (Low temp. Average)
Prated (High temp. Average)
SCOP (Low temp. Average)
SCOP (High temp. Average)
Outdoor Unit
Model Names
Indoor Unit
Cooling
Capacity
(Rated)
Heating
Cooling
Power Input
(Rated)
Heating
EER
Cooling
COP
Heating
Prated (Low temp. Average)
Prated (High temp. Average)
SCOP (Low temp. Average)
SCOP (High temp. Average)
Outdoor Unit
Model Names
Indoor Unit
Cooling
Capacity
(Rated)
Heating
Cooling
Power Input
(Rated)
Heating
EER
Cooling
COP
Heating
Prated (Low temp. Average)
Prated (High temp. Average)
SCOP (Low temp. Average)
SCOP (High temp. Average)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And "Electric characteristics" chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Anechoic chamber. Therefore, these values depend on the ambient conditions and values are normally higher
in actual operation.
4. Performances are based on the following conditions :
• Cooling : Inlet/Outlet Water Temp. 23°C/18°C, Outdoor Air Temp. 35°CDB / 24°CWB
• Heating : Inlet/Outlet Water Temp. 30°C/35°C, Outdoor Air Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
5. This product contains Fluorinated greenhouse gases.
AHUW056A3 [HU051 U43]
AHNW16606A3 [HN1616 NK3]
kW
5.0
kW
5.0
kW
1.09
kW
1.01
W/W
4.60
W/W
4.93
kW
5.50
kW
5.60
W/W
4.52
W/W
3.23
AHUW096A3 [HU091 U43]
AHNW16606A3 [HN1616 NK3]
kW
9.0
kW
9.0
kW
2.37
kW
2.05
W/W
3.80
W/W
4.40
kW
6.50
kW
5.60
W/W
4.34
W/W
3.23
AHUW146A3 [HU141 U33]
AHNW16606A3 [HN1616 NK3]
kW
12.0
kW
14.0
kW
3.08
kW
3.18
W/W
3.90
W/W
4.41
kW
9.50
kW
9.90
W/W
4.45
W/W
3.32
Outdoor unit
AHUW076A3 [HU071 U43]
AHNW16606A3 [HN1616 NK3]
7.0
7.0
1.56
1.47
4.50
4.75
6.00
5.60
4.45
3.23
AHUW126A3 [HU121 U33]
AHNW16606A3 [HN1616 NK3]
10.4
12.0
2.60
2.64
4.00
4.55
9.00
9.90
4.45
3.32
AHUW166A3 [HU161 U33]
AHNW16606A3 [HN1616 NK3]
13.0
16.0
3.60
3.76
3.61
4.26
10.00
9.90
4.30
3.32
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents