Download Print this page

Installation - Graco 226086 Instructions Manual

Air driven, 5 gal. (19 liter) size agitators

Advertisement

WARNING
FIRE AND EXPLOSION HAZARD
Always maintain a minimum of 1 in.
clearance between rotating agitator parts
and container to prevent sparks from
contact.
Typical Installation
air line lubricator
air line filter
air regulator
and gauge
NOTE: The reference numbers and letters in paren-
theses in the text refer to the Parts Drawing and Fig. 1.
Air Requirements
For continuous use, the 1/4 HP air motor typically
requires 2 cfm (0.06 m#/min) of air.
4
306670

Installation

agitator motor
mix tank
(reference only)
Preparing the Agitator for Use
1. Set the air motor (B) in the opening in the cover (1)
as shown in Fig. 1. Secure with the two setscrews
(5), using the allen wrench (4).
2. Slide the coupling (F) onto the shaft (A) of the air
motor, then insert the agitator shaft (G) into the
coupling. Secure the coupling with the two set-
screws (E).
3. Close the needle valve (D). Install an air line quick
disconnect to the air inlet. Order Part No. 208536
coupler and 169969 fitting, 1/8 npt(m). Then con-
nect a properly sized air hose to the 1/8 npt(f) inlet
of the valve.
4. Position the agitator and cover assembly on top of
a 5 gal. (19 liter) pail of paint (P). Tighten the three
thumbscrews (3).
5. Remove the cap gasket (6) and install a suction
tube (M) in the largest port (Q) near the center of
the cover. Adjust the suction tube so its end is
about 1/4 in. (6 mm) above the bottom of the pail.
Secure the tube in the port with three thumb-
screws (3).
NOTE: The smaller port (N) is for use in a recirculation
system.
6. Ground the agitator. See instructions on page 6.