Monitor Interface

Contrast Control
Potential Balancing
Use the controls on the monitor to set the appropriate brightness and contrast.
The switch for the terminal resistor may only be switched to "High" if another operator panel
or another monitor is connected via the "OUT" BAS socket. For operation without continued
looping of the monitor signal, set the switch to "75E".
The 24V output is for voltage supply of the keyboard encoder only.
Running the monitor at full contrast reduces the CRT's useful life.
©
Siemens AG 1992 All Rights Reserved
WS 400-30/WS 400-50 (Description)
OUT 75E HIGH IN
RED
OUT 75E HIGH IN
GREEN/CS
OUT 75E HIGH IN
BLUE
OUT 75E HIGH IN
HS/CS
OUT 75E HIGH IN
VS
0V
24V
Switch for Terminal Resistors
6ZB5 440-0KP02
Brightness Control
Maintenance Connector (Monitor)
Screen Ground
CS Composite Sync
HS Horizontal Sync
VS Vertical Sync