Hardware Requirements; Converter - Siemens SIMODRIVE 611U Product Information

Connecting to the technology cpu
Table of Contents

Advertisement

Hardware Requirements

2.1

Converter

611U converter
● SIMODRIVE 611U closed-loop control module
● Optional PROFIBUS DP3 module for isochronous PROFIBUS
Closed-loop control module options:
2axis
2axis
2axis
2axis
1axis
1axis
Optional module
Note
As a general principle, a closed-loop control card for speed setpoint operation is sufficient for
operation with the technology CPU. This is also the case when DSC is used.
If you want to use an external encoder on the axis, you must select a 2-axis closed-loop
control module, whereby the second axis cannot be used to control a motor.
POSMO SI
SIMODRIVE POSMO SI is a complete 1-axis function unit. It consists of the following:
● Power section
● Control electronics
● Motor
Order number: 6SN2 4xx-2BF00-0Gxx
Connecting the SIMODRIVE 611U to the Technology CPU
Product Information, 03/2008, A5E00272066-05
for sin/cos 1 Vpp speed setpoint
encoder
for sin/cos 1 Vpp positioning
encoder
for n-set resolver
for resolver positioning
for n-set resolver
for resolver positioning
PROFIBUS DP3
6SN1118-0NH0x-0AAx
6SN1118-1NH0x-0AAx
6SN1118-0NK0x-0AAx
6SN1118-1NK0x-0AAx
6SN1118-0NJ0x-0AAx
6SN1118-1NJ0x-0AAx
6SN1114-0NB01-0AA0