Drain Water; Relocation; Noise; Notes On Electrical Wiring - GE AEE07KP Service Manual

Window type
Hide thumbs Also See for AEE07KP:
Table of Contents

Advertisement

Drain Water

To maximize cooling efficiency, the air conditioner is designed to spray condensate on to the
condenser coil.
For cooling only unit: Should the spraying sound annoy you, please adopt the method of outside drain
with the following steps, which may however cause a small loss of performance.
1. Slide out the unit from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the bottom of the drain pan.
5. Slide the unit into its original place in the cabinet.
Note:
Drain pan and drain hose must be installed before operation.
Drain hose or tubing can be purchased locally to satisfy your particular needs.
Notes for Installation

Relocation

Contact your seller when the unit is to be relocated. Relocation of the
unit shall be performed under the guidance or with the assistance of
a trained, qualified technician. Charges concerning relocation of the unit
shall be borne by the user.

Noise

Install in a location firm enough to minimize the noise and vibration of
operation.
Do not put anything in front of the outlet of the unit to avoid increasing
noise.
Make sure the noise and the hot air discharged will not disturb your neighbors.
Should there be any abnormal sound during operation, contact your seller instantly
please adopt a safety support.
The temperature of refrigerant circuit will be high, please keep the interconnection
cable away from the copper tube.
Electrical Wiring
Make sure the unit is reliably grounded.
Adopt an exclusive circuit for the unit. Never apply removable socket, or the poor
contact between them may lead to overheating or fire.
Never pull the power cord with excessive force.
In a fixed circuit, make sure there is electricity leakage protection switch with leakage
current less than 30mA.
Connection between air conditioner and its power cord, as well as between individual
elements should be in accordance with the wiring diagram on the unit.
Make sure the air conditioner is installed in accordance with national wiring regulation.
Adopt an all-pole disconnection switch with a minimum contact separation of 3mm in all poles
in a fixed wiring
Make sure an air switch (thermal-magnetic breaker) is installed in the circuit.
Damaged power cord should be replaced by the manufacturer, an authorized dealer
or a qualified person for fear of hazards.
All electrical work should be performed in accordance with local wiring regulations.
36
Screws
Drain Pan
Internal View
Drain Hose
External View
Service Manual
Installation and Maintenance