Other Functions & Settings; Headphone Monitor Functions; Connecting Audio Signals; Monitoring On Headphones - Tascam RC-601mkII Owner's Manual

Remote control unit
Hide thumbs Also See for RC-601mkII:
Table of Contents

Advertisement

OTHER FUNCTIONS & SETTINGS

Headphone Monitor Functions

On the RC-601MKII, you can input stereo audio output
signals (max. 4 systems) from external equipment, and
monitor these signals using the headphone connected to the
PHONES terminal.

Connecting Audio Signals

Stereo audio signals of up to four systems can be input to
the MONITOR IN terminal on the rear panel.
Connect to the audio output (max. output level: +6 dBV,
unbalance) of the external equipment according the
following pin arrangement.
[NOTE]
The MONITOR IN terminal must be connected to also
when the audio output signal of the CD-601MKII that is
connected to the RC-601MKII is to be monitored.
13
25
MONITOR IN Pin Arrangement
Pin No. Signal Name
1
Lch IN1
Monitor input 1 Lch
2
Rch IN1
Monitor input 1 Rch
3
N.C.
4
Lch IN2
Monitor input 2 Lch
5
Rch IN2
Monitor input 2 Rch
6
N.C.
7
Lch IN3
Monitor input 3 Lch
8
Rch IN3
Monitor input 3 Rch
9
N.C.
10
Lch IN4
Monitor input 4 Lch
11
Rch IN4
Monitor input 4 Rch
12
N.C.
13
N.C.
14
Lch GND1
Monitor input 1 Lch shielded
15
Rch GND1
Monitor input 1 Rch shielded
16
N.C.
17
Lch GND2
Monitor input 2 Lch shielded
18
Rch GND2
Monitor input 2 Rch shielded
19
N.C.
20
Lch GND3
Monitor input 3 Lch shielded
21
Rch GND3
Monitor input 3 Rch shielded
22
N.C.
23
Lch GND4
Monitor input 4 Lch shielded
24
Rch GND4
Monitor input 4 Rch shielded
25
N.C.

Monitoring on Headphones

Select the headphone monitor source using the MONITOR
SELECT knob. The selected source signal is output from
the PHONES terminal.
Adjust the monitor level using the LEVEL knob.
The remote control unit can be operated referenced to an
external digital clock.
1 Connect the word clock from an external source to
2 Set menu No. 04 ("CLOCK") to "EXT".
1
The default setting is "INT" (referenced to internal clock).
14
The failsafe function is a safety function for preventing
playback from discontinuation when an operation key is
touched inadvertently during a final take.
In the default setting, the failsafe function is ON, and
operation of keys other than STOP, PLAY MODE and
DISPLAY MODE is not accepted during online playback.
Also, in the online READY mode, operation of search-
related keys such as the TRACK key and numeric keys and
the MENU key is not accepted.
[NOTE]
When the failsafe function is set to OFF at menu item No.
10 ("F_SAFE"), all keys (excluding SEARCH dial, FLASH
READY key and MEMO key in the online playback mode)
are functional.
The failsafe function ON/OFF setting is valid on both the
CD-601MKII and the RC-601MKII.
Referencing to an External Clock
Source
the WORD SYNC IN terminal on the rear panel of the
CD-601MKII.
"EXT CLK" and the sampling frequency ("44.1k" or "48k")
are lit on the clock display area of the display area.

Failsafe Function

Even when the failsafe function is ON, entry by the
numeric keys is accepted in the direct cue point locate
mode and flash start mode.
25
TASCAM RC-601MKII

Advertisement

Table of Contents
loading

Table of Contents