Samsung AC026NNNDKH Service Manual page 41

System air conditioner, mini 4 way cassette series
Table of Contents

Advertisement

Option
SEG13
Function
Page
Indication
Details
Indication
and details
2
Option
SEG19
Function
Page
Indication
Details
Indication
and details
3
• Even if you set the Use of drain pump (SEG8) option to 0, it is automatically set to 2 (the drain pump is used with 3 minute delay).
• If you set the Maximum filter usage time (SEG18) option to a value other than 2 and 6, it is automatically set to 2 (1000 hours).
• If you set the Individual control with remote control (SEG20) option to a value other than 0 to 4, it is automatically set to 0
(Indoor 1).
• Each model's compensation of the wind-free fan RPM (SEG11) option has to be set by default.
• Compensation of the wind-free fan RPM (SEG11) option adjusts 20 rpm per 1 step.
4-8
SEG14
Use of external
Setting the output
control
of external control
Indication
Details
Indication
0
Disuse
0
On/Off
1
control
2
Off control
1
Window
on/off
3
control
SEG20
Individual control
Heating setting
with remote
compensation
control
Indication
Details
Indication
0 or 1
Indoor 1
0
2
Indoor 2
1
3
Indoor 3
2
4
Indoor 4
SEG15
SEG16
S-Plasma ion
Details
Indication
Details
Thermo
0
Disuse
on
Operation
1
on
SEG21
SEG22
Details
0°C
(default)
Reserved
2°C
5°C
SEG17
Buzzer control
Indication
Details
Use of
0
buzzer
Disuse
Use
1
of
buzzer
SEG23
Reserved
Samsung Electronics
SEG18
Maximum filter
usage time
Indication
Details
1000
0
hours
2000
1
hours
SEG24