Make sure to properly secure the arm mounting hardware.
-
Mount the cartridge to the head-shell using steel or aluminium screws to allow a rigid
-
installation.
Tighten the screws so the cartridge can be moved in the headshell.
-

Precisely align the phono cartridge

Block the platter to prevent it from turning
-
Aime the calibrator disc on the platter over the mat
-
Adjust the stylus pressure to approx. 1 gram.
-
Move the tone arm and cue it down on the alignment grid
-
Check for the arm tube to be horizontal with the surface of the platter and adjust the
-
height accordingly
Bring the tone arm over the center of the grid again and lower it. The stylus tip must fit in
-
the pin hole in the center of the grid. If not, position the cartridge so it does.
Precisely align the body of the cartridge with the lines on the grid.
-
Secrure the cartridge screws and repeat the preivous operation.
-
Check the azimuth by lowering the stylus over the black portion on the calibrator disc. The
-
reflection will help determine if the cartridge is off its vertical axis.
Note: The azimuth is the vertical position of the stylus relative to the record groove when
-
viewing it from the front. The proper setting is 90degrees.
Check the stylus pressure and adjust to specifications
-
Install the stylus guard to complete the assembly of your Alexandria
-