Picture Distortion Adjustment - Sony Trinitron KV-AR212M83 Service Manual

Table of Contents

Advertisement

GEOM :
000
HPOS
001
HPAR
002
HBOW
003
VLIN
004
VSCR
005
HSIZ
006
EWPW
007
UCOP
008
LCOP
009
EWTZ
010
VSLP
011
VSIZ
012
SCOR
013
VPOS
014
HBL
015
WBF
016
WBR
017
SBL
018
COPY
5. Write into memory by pressing [MUTING] then
the remote commander.
WIDE MODE (50Hz)
(V-Compression Adjustment)
1. Input SPCB signal.
2. Adjust condition change to WIDE MODE : ON
3. Copy (Item from normal mode 50Hz) all Normal
Mode adjusted data.
NORMAL MODE (60Hz)
1. Input 525/60Hz signal.
2. They can copy 50Hz first.
("COPY" under GEOM is set to
3. Using the
and
button, select category GEOM
1
4
(Service Mode).
4. Raise/lower data using the
obtain optimum image.
GEOM :
000
HPOS
001
HPAR
002
HBOW
003
VLIN
004
VSCR
005
HSIZ
006
EWPW
007
UCOP
008
LCOP
009
EWTZ
010
VSLP
011
VSIZ
012
SCOR
013
VPOS
014
HBL
015
WBF
016
WBR
017
SBL
018
COPY
Horizontal Shift (HS)
Horizontal Parallelogram
Horizontal Bow
Vertical Linearity
Vertical Scroll
EW Width (EW)
EW Parabola/Width (PW)
EW Upper Corner Parabola
EW Lower Corner Parabola
EW Trapezium
Vertical Slope (VS)
Vertical Amplitude
S-Correction (SC)
Vertical Shift (VSH)
RGB Blanking Mode
Timing of Wide Blanking (WBF)
Timing of Wide Blanking (WBR)
Service Blanking
Copy the GEOM data to all
50/60Hz NVM area
on
-
, then [MUTE] +
1
-
and
buttons to
3
6
Horizontal Shift (HS)
Horizontal Parallelogram
Horizontal Bow
Vertical Linearity
Vertical Scroll
EW Width (EW)
EW Parabola/Width (PW)
EW Upper Corner Parabola
EW Lower Corner Parabola
EW Trapezium
Vertical Slope (VS)
Vertical Amplitude
S-Correction (SC)
Vertical Shift (VSH)
RGB Blanking Mode
Timing of Wide Blanking (WBF)
Timing of Wide Blanking (WBR)
Service Blanking
Copy the GEOM data to all
50/60Hz NVM area
KV-AR212M50/AR212M83/AR212M61
WIDE MODE (60Hz)
(V-Compression Adjustment)
1. Input mono scope signal.
2. Adjust condition change to WIDE MODE : ON
3. "COPY" is set to
3-5.

PICTURE DISTORTION ADJUSTMENT

H. CENTER ADJUSTMENT (HPOS)
1. Input Monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select the HPOS item with
4. Adjust the value of HPOS with
vertical center.
5. Press [MUTING] then
H. SIZE ADJUSTMENT (HSIZ)
1. Input Monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select HSIZ with
4. Adjust with
and
3
5. Press [MUTING] then
V. SIZE ADJUSTMENT (VSIZ)
1. Input Monoscope signal.
)
2. Activate the Service Adjustment Mode.
3. Select the VSIZ item with
4. Adjust value of VPOS with
vertical center.
5. Press [MUTING] then
V. CENTER ADJUSTMENT (VPOS)
1. Input Monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select the VPOS item with
4. Adjust value of VPOS with
vertical center.
5. Press [MUTING] then
– 31 –
RM-W101
, then [MUTE] +
1
-
and
.
1
4
and
for the best
3
6
to save into the memory.
-
and
.
1
4
for the best horizontal size.
6
to save into the memory.
-
and
.
1
4
and
for the best
3
6
to save into the memory.
-
and
.
1
4
and
for the best
3
6
to save into the memory.
-
RM-W100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron kv-ar212m61Trinitron kv-ar212m50

Table of Contents