2) Standard specifications (large capacity types) [Note 1]
Item
Voltage class
Applicable motor (kW)
Applicable motor (HP)
Type
Form
Output capacity
(kVA) [Note 2]
Output current
(A)
Output voltage
Overload
current rating
Dynamic braking
circuit
Dynamic braking
resistor
Voltage-frequency
[Note 3]
Allowable
fluctuation
Protective method
(IEC60529)
Cooling method
Cooling fan noise (dBA)
Color
EMC filter
DC reactor
Item
Voltage class
Applicable motor (kW)
Applicable motor (HP)
Type
Form
Output capacity
(kVA) [Note 2]
Output current
(A)
Output voltage
Overload
current rating
Dynamic
braking circuit
Dynamic braking
resistor
Voltage-frequency
[Note 3]
Allowable
fluctuation
Protective method
(IEC60529)
Cooling method
12
Cooling fan noise (dBA)
Color
EMC filter
DC reactor
Note 1: For 200V-55kW, 400V-90kW or larger model, be sure to install DC reactor.
However, this is unnecessary for DC input specifications.
Note 2: Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 3: An external power supply backup available (optional) (Type: CSP002Z)
Note 4: ±10% when the inverter is used continuously (load of 100%).
Note 5: Models, 200V-18.5kW or more and 400V-22kW or more, do not have wiring port covers. They have large
openings, but there is no space to bend the external cables inside the unit.
Note 6: Three-phase 380~480V-50/60Hz for 4900PC
55
75
2550P
84
221
Three-phase 200V~240V (The maximum output voltage is equal to the input supply voltage.)
Voltage + 10% - 15% [Note 4]
61
90
110
132
125
150
200
4900PC
4110KPC
4132KPC
136
164
197
179
215
259
Three-phase 380V~480V (The maximum output voltage is equal to the input supply voltage.)
Built-in dynamic braking drive circuit
[Note 6]
Voltage + 10% - 15% [Note 4]
61
72
73
Specification
200V class
VFAS1-
150%-1 minute, 165%-2 sec.
Built-in dynamic braking drive circuit
An external braking resistor (optional)
Rating: Refer to 5.19.
Three-phase 200~240V-50/60Hz
Frequency ±5%
IP00 Open type [Note 5]
Forced air-cooled
RAL7016
External filter (optional)
Attached DC reactor
Specification
400V class
160
200
220
250
300
350
VFAS1-
4160KPC
4200KPC
4220KPC
239
295
325
314
387
427
150%-1 minute, 165%-2 sec.
External dynamic braking circuit (optional)
An external braking resistor (optional)
Rating: Refer to 5.19.
Three-phase 380~440V-50Hz
Three-phase 380~480V-60Hz
Frequency ±5%
IP00 Open type [Note 5]
Forced air-cooled
73
76
76
RAL7016
Built-in
Attached DC reactor
L-2
E6581301 
75
100
2750P
109
285
72
280
355
400
450
550
600
4280KPC
4355KPC
4400KPC
419
511
578
550
671
759
76
76
76
500
700
4500KPC
717
941
78

Advertisement