Suunto D4 User Manual page 12

Suunto d4 divers watch user's guide
Table of Contents

Advertisement

WARNING
WARNING
WARNING
THE DIVE COMPUTER WILL NOT ACCEPT FRACTIONAL
PERCENTAGE VALUES OF OXYGEN CONCENTRATION. DO
NOT ROUND UP FRACTIONAL PERCENTAGES! For example,
31.8% oxygen should be entered as 31%. Rounding up will cause
nitrogen percentages to be understated and will affect decompres-
sion calculations. If you want to adjust the computer to provide
more conservative calculations, use the personal adjustment
feature to affect decompression calculations, or reduce the PO
setting to affect oxygen exposure.
SELECT THE CORRECT ALTITUDE ADJUSTMENT SETTING!
When diving at altitudes greater than 300 m/1,000 ft the Altitude
Adjustment feature must be correctly selected in order for the
computer to calculate the decompression status. The dive com-
puter is not intended for use at altitudes greater than 3,000
m/10,000 ft. Failure to select the correct Altitude Adjustment set-
ting, or diving above the maximum altitude limit will result in erro-
neous dive and planning data.
SELECT THE CORRECT PERSONAL ADJUSTMENT SETTING!
Whenever it is believed that factors that tend to increase the
possibility of DCI exist, it is recommended that you use this option
to make the calculations more conservative. Failure to select the
correct Personal Adjustment setting will result in erroneous dive
and planning data.
2
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents