JVC AV32L5EKGY Service Manual page 29

Table of Contents

Advertisement

AV32L5EKGY
AV32L5EIGY
Measuring
Item
instrument
Adjustment
Signal
of TRAPEZ
generator
Remote
control unit
Adjustment of
Signal
CORNER
generator
UP/ LOW
Remote
control unit
Straight
Adjustment of
Signal
ANGLE
generator
Remote
control unit
28
Test point
Adjustment part
5.TRAPEZ
Parallel
7.COR-PIN
8.COR-UP
9.COR-LO
Straight
10.ANGLE
PARALLELOGRAM
25. Receive a cross-hatch signal.
26. Select 5.TRAPEZ with the FUNCTION UP/DOWN key.
27. Set the initial setting value of TRAPEZ with the FUNCTION -
or + key.
28. Adjust TRAPEZ and bring the VERTICAL lines at the right and
left edges of the screen parallel .
29. Press the MENU key and memorize the set value.
30. Select 9.COR-LO with the FUNCTION UP / DOWN key.
31. Set the initial setting value of COR-LO with the FUNCTION –
or + key.
32. Adjust COR-LO, and bring the lines at the low corner straight.
33. Select 8.COR-UP with the FUNCTION UP / DOWN key.
34. Set the initial setting value of COR-UP with the FUNCTION –
or + key.
35. Adjust COR-UP, and bring the lines at the upper corner
straight.
36. If the extreme upper & lower corners have pin or barrel
condition a little, chose 7.COR-PIN and adjust it to get the
straight.
37. Press the MENU key and memorize the set value.
" In case which there is a parallelogram distortion of images on
the screen.
38. Select 10.ANGLE with the FUNCTION UP / DOWN key.
39. Adjust ANGLE, and bring the VERTICAL lines straight.
40. Press the MENU key and memorize the set value.
No. 51779
Description

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Av32l5eigy

Table of Contents