Operation; Wire/Plug-In Bridges; Setting Of The Hold-Open Time (Trimmer P1) - Chamberlain GAROG TST-2 Operational Description

Door control device
Table of Contents

Advertisement

Operational Description TST WS-B
7

Operation

The main operating elements of the TST-WS-A door control device are in the top right corner of the plate when
viewed straight on.
Wire bridge P2
(reversing time)
Trimmer P1
(hold-open time)
Operation
Security strip
RUN-LED
SILEI-LED
(green)
(yellow)
Fig. 8.1: Operating elements of the TST WS-B

7.1 Wire/plug-in bridges

Bridge/Jump
Function
er
Bridge P2
Reversing time
closed
broken
Bridge P3
Relay function K2
closed Fault output
broken Yard light
Jumper
Security strip
JP400
1-2
2-3

7.2 Setting of the hold-open time (trimmer P1)

It effects the automatic closing travel of the door after expiry of this
time from the upper end position or the intermediate holding position.
The hold-open time is activated by the switching of the DIP2 switch
into the ON position.
It can lie within the range of 1s to approx. 320s. The setting range is
illustrated in the bottom of the Figure.
An active emergency stop input or a stop command deactivates the
hold-open time.
The hold-open time only runs out after release of all open commands
and security devices.
The hold-open time is deactivated with three closing travel attempts
take place one after the other, wherein the security strip has been actuated.
Wsb_bse8.doc
Wire bridge P3
DIP-switch
(relay function K2)
1
ON
1 2 3 4 5 6 7 8
3
Emergency stop
Diagnosis
NOTST-LED
INKR-LED
(red)
(green)
Reaction
Dwell time before changing travel direction (contactor switch over)
reversal of security strip
0.25s
-
0.05s
-
"Fault indicator relay" (fault exists if after 5 minutes of permanent
holding of stop, open, emergency stop, light barrier or draw-in
security device, no automatic operation is possible.
Exception: Open/stop commands, light barriers or security strip are
in upper end position/intermediate holding is not yet engaged.
"Yard light actuating pulse" (1s pulse before each commencement of
travel to actuate an automatic staircase device)
Terminating resistor of the security strip
1.2kΩ
-
8.2kΩ
-
Jumper 400
(security strip)
mt 041102
Page: 8
Note :
Adjustments of the
control elements can
only be made by
instructed personnel
approx. 60s
range
from 1s up to 60s
from 60s up to 320s
approx. 1s
approx. 320s
Fig. 8.2: setting range of trimmers P1
FEIG ELECTRONIC GmbH
range