Page 3
90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period.
Page 4
This device complies with the FCC rules only if used with shielded interface cables of suitable quality and construction. National Instruments used such cables to test this device and provides them for sale to the user. The use of inferior or nonshielded interface cables could void the user's authority to operate the equipment under the FCC rules.
Page 6
Using the Keyboard with WinBIOS Setup ............ 4-2 WinBIOS Main Menu....................4-3 Chapter 5 Peripherals Software Installation .....................5-2 Why National Instruments Does Not Install All Peripheral Drivers....5-2 Installing Peripheral Drivers ................5-2 Video..........................5-3 About the Trident Video Manual ..............5-3 Technical Information about the Video Interface ..........5-3 IDE..........................
Page 11
VXI computers, lists what you need to get started, describes the hardware, and lists optional equipment and software. • Chapter 2, Functional Overview, contains functional descriptions of each major logic block on the VXIpc-850 Series embedded computer. • Chapter 3, Configuration and Installation, contains the instructions to configure and install the VXIpc-850 Series embedded computer.
Page 12
VXIpc-850. • Appendix G, Customer Communication, contains forms you can use to request help from National Instruments or to comment on our products and manuals. • The Glossary contains an alphabetical list and description of terms used in this manual, including abbreviations, acronyms, metric prefixes, mnemonics, and symbols.
Page 13
Refer to the following manuals for more information about the hardware or software. This manual, the VXIpc-850 Series User Manual, contains more details about changing the installation or configuration from the defaults, and using the hardware.
Page 14
VXI-6, VXIbus Mainframe Extender Specification, Rev. 1.0, VXIbus Consortium Customer Communication National Instruments wants to receive your comments on our products and manuals. We are interested in the applications you develop with our products, and we want to help if you have problems with them.
VXI high-performance backplane capabilities and give you direct control of VXI registers, memory, interrupts, and triggers. All models in the VXIpc-850 Series are fully VXIplug&play compliant and are compatible with PC-compatible software tools, the National ®...
Hardware Description The VXIpc-850 Series controllers feature a modular, PCI-based local bus design that makes it easy to use interchangeable daughterboards to upgrade your controller to new microprocessors, without having to replace the motherboard or enclosure.
Appendix A, Specifications. Slot 0 Functionality You can use the VXIpc-850 Series computers to achieve full VXI Slot 0 control of your VXI system. You can also install the VXIpc-850 in another slot and use it in Non-Slot 0 mode. You do not have to...
Chapter Functional Overview This chapter contains functional descriptions of each major logic block on the VXIpc-850 Series embedded computer. VXIpc-850 Functional Description The VXIpc-850 is a modular PC in a dual-slot VXIbus C-size form factor. It includes many high-performance peripherals that normally require add-in cards on desktop PCs.
Page 23
Instruments ASIC developed to efficiently manage data transfers between the VXIbus and the processor (via the PCI bus). The MANTIS ASIC (also developed by National Instruments) performs VXIbus arbitration and manages interrupts and triggers. Also part of the VXIbus interface are the SMB connectors, which you can use to route triggers and the CLK10 signal to or from the VXIbus.
Installation This chapter contains the instructions to configure and install the VXIpc-850 Series embedded computer. Unless otherwise noted, these instructions apply to all models in the VXIpc-850 Series. Warning: Electrostatic discharge can damage several components on your VXIpc -850 module. To avoid such damage in handling the module, touch the antistatic plastic package to a metal part of your VXI chassis before removing the VXIpc-850 from the package.
VXIEDIT is the software configuration utility in the NI-VXI software. This utility is described in Chapter 3, NI-VXI Configuration Utility, in the NI-VXI Software Manual for the VXIpc-850 Series . You can use this utility to edit the configuration of the VXIpc-850. Some of these settings are stored in files that are read by the NI-VXI software, while other settings are stored directly in the VXIpc-850 EEPROM.
Chapter Peripherals This chapter contains brief descriptions of each of the peripheral components of the VXIpc-850 Series embedded computer. Table 5-1 lists the VXIpc-850 peripheral components. Refer to the VXIpc-850 Peripherals User Manual for more complete information on each peripheral.
This chapter contains information on how to install these drivers. Why National Instruments Does Not Install All Peripheral Drivers Although all drivers run concurrently with each other and can all run together, each driver uses a certain amount of system resources.
16 bytes of I/O space for all communication. Configuring Your Ethernet Addresses National Instruments programs the Ethernet address and other values into a serial EEPROM from which the 91C92 loads its power-on configuration. The defaults should be adequate for most situations;...
TCP/IP. If the driver you need is not supplied in the c:\images\enet directory, you can either contact National Instruments for help on finding the driver you need or, if you have internet access, you can access the Microsoft WWW or FTP sites, which contain some standard network drivers.
The software required for a PCMCIA interface, known as card- and-socket services, is provided by SystemSoft Corporation. National Instruments includes CardWizard to users who order the VXIpc-850 with DOS/Windows 3.1. CardWizard is a complete package of card-and-socket services with built-in diagnostic capabilities to help diagnose common PCMCIA problems.
VXIpc-850 with a full GPIB Talker/Listener/Controller functionality. This ASIC gives the VXIpc-850 complete compatibility with the National Instruments AT-GPIB/TNT. In fact, the default base address, interrupt level, and DMA level are the same on the VXIpc-850 as they are on the AT-GPIB/TNT.
• User-defined panel is required on the expansion boards based on National Instruments blank PCI or ISA panels. Contact National Instruments for a list of specifications for user-defined panels. As an alternative, you can modify the blank panels provided with the VXIpc-850.
Page 81
If your application requires a special type of video display, you can remove the PCI video card included with your VXIpc-850. Contact National Instruments for information on how to do this. What kind of monitor can I use with the VXIpc-850?
Page 83
Can I upgrade my VXIpc-850? You can upgrade the modular CPU card to upgrade the processor. Contact National Instruments for information. What should I do if I cannot boot from the hard disk? Make sure the IDE block is set to Auto, LBA is enabled, and 32-bit disk access is disabled.
Electronic Services Bulletin Board Support National Instruments has BBS and FTP sites dedicated for 24-hour support with a collection of files and documents to answer most common customer questions. From these sites, you can also download the latest instrument drivers, updates, and example programs. For recorded instructions on how to use the bulletin board and FTP services and for BBS automated information, call (512) 795-6990.
Page 85
Fax and Telephone Support National Instruments has branch offices all over the world. Use the list below to find the technical support number for your country. If there is no National Instruments office in your country, contact the source from which you purchased your software to obtain support.
Page 86
National Instruments for technical support helps our applications engineers answer your questions more efficiently. If you are using any National Instruments hardware or software products related to this problem, include the configuration forms from their user manuals. Include additional pages if necessary.
Page 87
Complete a new copy of this form each time you revise your software or hardware configuration, and use this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions more efficiently.
Page 88
NI-VXI Software Settings NI-VXI Software Version Number __________________________________________________ Using VXIedit or VXItedit?________________________________________________________ Logical Address _________________________________________________________________ Device Type ___________________________________________________________________ Address Space __________________________________________________________________ VXI Shared RAM Size ___________________________________________________________ Shared RAM Pool (Windows) _____________________________________________________ Byte Order for Lower Half Window _________________________________________________ Byte Order for Upper Half Window _________________________________________________ Mapping Scheme for Lower and Upper Half Windows of VXI Shared RAM _________________ ______________________________________________________________________________ Resource Manager Delay _________________________________________________________...
Page 89
VXI Slave Auto Retry ____________________________________________________________ VXI Transfer Limit ______________________________________________________________ User Window Base ______________________________________________________________ User Window Size _______________________________________________________________ User Window Below 1 MB ________________________________________________________ Driver Window Base _____________________________________________________________ Driver Window Size _____________________________________________________________ Driver Window Below 1 MB ______________________________________________________ Other Products Mainframe Make and Model _______________________________________________________ Microprocessor _________________________________________________________________ Clock Frequency ________________________________________________________________ Type of Video Board Installed _____________________________________________________...
Page 90
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: VXIpc™-850 Series User Manual Edition Date: April 1996 Part Number: 321124A-01 Please comment on the completeness, clarity, and organization of the manual.
Page 95
Glossary megabytes of memory MITE A National Instruments custom ASIC, a sophisticated dual- channel DMA controller that incorporates the Synchronous MXI and VME64 protocols to achieve high-performance block transfer rates MODID Module ID Lines. Used in VXI to geographically locate boards...