IBM System/370 145 Operating Procedures Manual page 44

Hide thumbs Also See for System/370 145:
Table of Contents

Advertisement

Reliability Report Illustration
REPORT OS-Indicates the
number of reports since the
start of the test.
0001 MIN, 40 SEC-Indicates
the elapsed time since the last
report.
CLOCK=OO/OO/OO-Indicates
clock setting at time of report.
r ____
--.lREPORT 08 0001 MIN, 40 SEC
CLOCK=OO/OO/OO
I/O BLOCKS-Indicates the
total number of I/O blocks run.
CPU-Indicates the number of
operations and failures against
each class of CPU test.
I/O UNITS-Itemizes informa-
tion about the I/O units (see
chart).
BLOCKS
OPERATED
FAILED
I/O
000529
000013
CPU
FIXED PT
005371
FLOAT PT
001020
DECIMAL
000612
000000
000000
000000
I/O UNITS
BLOCKS
ACUM
ADDRESS CLAS OPER FAIL STAT
00001F
TY
0000 0000
000190
DS
0058 0000
000191
DS
0059 0000
000193
DS
0057 0013 OEOO
000280
TP
0355 0000
000281
TP
0000 0000
000282
TP
0000 0000
000283
TP
0000 0000
NOT
RDY
NOTE
RDY
*UNIT ERROR*
CE,DE,UCK
This line indicates the failing device.
The information on this line should
be given to the dispatcher when
calling for service.
ADDRESS
Unit address of the device
CLAS
Denotes the class of the unit (TP=Tape)
OPER
Indicates the number of I/O blocks run by this unit
FAIL
Number of failures for the unit
ACUM STAT
Total status accumulated by the unit since the last report
NOT RDY
Indicates a change of unit status to not ready
RDY
Indicates a change of unit status to ready
*CHAN ERROR*
Error against the channel
*C U ERROR*
Error against the control unit
*UNIT ERROR-
Error against the unit
Operating Procedures
43

Advertisement

Table of Contents
loading

Table of Contents