Ranger RS-500-D-601 Installation And Operation Manual page 19

Spray-wash cabinets
Table of Contents

Advertisement

Troubleshooting
Issue
Pump and heaters not working.
Cleaning quality is poor.
Water/Detergent solution does not
get hot.
Pump motor comes on but is not
pumping or has little pressure.
Spray Nozzles and/or pump impeller
clog frequently.
Solution is foaming.
Rust inside cabinet.
Turntable not turning smoothly.
If you continue to have problems with your Spray-Wash Cabinet, visit
www.bendpak.com/support/
RS Series Spray-Wash Cabinets
Action to Take
Make sure the Spray-Wash Cabinet is getting power.
Check the Breakers; make sure they are On.
Make sure the right Detergent is being used.
Make sure the Spray Nozzles are not clogged.
Make sure the Water/Detergent solution is not dirty but is hot.
Make sure the Spray-Wash Cabinet is getting power
(Breakers on, Power Cord connected), then wait for the
temperature to rise to 160° to 180°F (71° to 82°C).
Make sure Water level is high enough; it should be just above
the bottom of the Grate.
Make sure the Spray Nozzles and/or pump impeller are not
clogged from the inside; if they are, clean them.
Use the Oil Skimmer and remove Sludge more often.
Clean or replace the Water/Detergent solution more often.
Remove the Spray Nozzles and/or pump impeller, and clean
them.
You are using the wrong Detergent; switch Detergents.
The Wash Cycle was started when the Water/Detergent
solution was cold;
160°F (71°C) before starting a Wash Cycle.
Detergent concentration is too low; add Detergent.
Water level is too low; add Water.
You are using the wrong Detergent; switch Detergents.
The Spray-Wash Cabinet is not being used enough; remove
the rust, then perform a Wash Cycle at least once a month.
Spray-Wash Cabinet was not started up correctly. Remove
rust with steel wool, change solution to twice the normal
Detergent level, then perform the Start-Up Process again.
Check the Friction-Drive Wheel for worn wire brushes. If worn,
replace with Ranger SKU 5335721.
or call Ranger Products at (805) 933-9970.
19
you must warm the solution to at least
P/N 5900245 — Rev. B7 — November 2019