Servicing a Kohler
This section is only for machines with Kohler engines.
If your engine looks like the one shown in
you have a Kohler engine.
Important:
Refer to your engine owner's manual
for additional maintenance procedures.
Figure 56
Servicing the Air Cleaner
Service Interval: Before each use or daily—For
Kohler engines—check the air
cleaner for dirty, loose, or damaged
parts.
Every 25 hours—For Kohler engines—service
or replace the air-cleaner foam element (more
often under dusty, dirty conditions).
Every 100 hours—For Kohler engines—replace
the air-cleaner paper element (more often under
dusty, dirty conditions).
Note:
Service the air cleaner more frequently if
operating conditions are extremely dusty or sandy.
®
Engine
Removing the Elements
Figure
56,
g036713
Servicing the Foam Element
50
1.
Rotate the latches outward.
2.
Remove the cover to access the air-cleaner
elements
(Figure
57).
Figure 57
1. Air-cleaner cover
3.
Remove the foam and paper elements
58).
4.
Remove the foam element from the paper
element
(Figure
58).
Figure 58
1. Air-cleaner cover
2. Foam element
1.
Wash the foam element in liquid soap and
warm water. When the element is clean, rinse
it thoroughly.
2.
Dry the element by squeezing it in a clean cloth.
Important:
Replace the foam element if it
is torn or worn.
g028105
2. Air-cleaner latch
(Figure
g028106
3. Paper element