Reading The Cpu Temperature And Environmental Limits - Sun Microsystems Netra CP2500 Programming Manual

For the solaris operating system
Table of Contents

Advertisement

Reading the CPU Temperature and
Environmental Limits
You can access the CPU temperature sensor current readings and environmental
monitoring settings from the Solaris prompt by typing the following commands.
Sample output is listed after each command.
prtpicl command example:
# prtpicl -c temperature-sensor -v
CPU-sensor (temperature-sensor, 2600000041f)
:Condition
:HighPowerOffThreshold
:HighShutdownThreshold
:HighWarningThreshold
:LowPowerOffThreshold
:LowShutdownThreshold
:LowWarningThreshold
:Temperature
:Label
:GeoAddr
:_class
:name
prtdiag command example:
# prtdiag -v
...
CPU Node Temperature Information
--------------------------------
Temperature Reading: 85
Critical Threshold Information
------------------------------
High Power-Off Threshold
High Shutdown Threshold
High Warning Threshold
Low Power Off Threshold
Low Shutdown Threshold
Low Warning Threshold
ok
123
118
110
-20
-10
-5
74
Ambient
0xe
temperature-sensor
CPU-sensor
123
118
110
-20
-10
-5
Chapter 2 Environmental Monitoring
41