Using The Show-Sensors Command At The Openboot Prom; Environmental Monitoring Application Programming - Sun Microsystems Netra CP2500 Programming Manual

For the solaris operating system
Table of Contents

Advertisement

Using the show-sensors Command at the
OpenBoot PROM
The show-sensors command at OpenBoot PROM displays the readings of all the
temperature sensors on the board. A sample output for typical sensor readings for a
Netra CP2500 is as follows:
ok show-sensors
Sensor#
Sensor Name
=======
====================================
1
EP 5v
2
EP 3.3v
3
BP +12v
4
BP -12v
5
IPMB Power
6
SMC Power
7
VDD 3.3v
8
VCCP
9
+12v
a
-12v
b
+5v
c
Standby 3.3v
d
Main 3.3v
e
External I
f
External II temp (Outlet) Sensor
10
Internal
ok
Environmental Monitoring Application
Programming
The following sections describe how to use the environmental monitoring functions
in an application program.
For the environmental monitoring application program (envmond) to monitor the
hardware environment, the following conditions must be met:
The system controller device driver must be installed.
The environmental monitoring application program (envmond) must be installed
and running.
34
Netra CP2500 Board Programming Guide • March 2007
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
temp (CPU)
Sensor
temp (Inlet)
Sensor
Sensor Reading
===================
(d1)
4.968 volts
(8b)
3.336 volts
(ce)
11.760 volts
(63)
-12.010 volts
(d2)
4.968 volts
(69)
2.448 volts
(a8)
3.2592 volts
(64)
1.1800 volts
(ba)
11.6250 volts
(36)
-12.040 volts
(be)
4.940 volts
(be)
3.2680 volts
(be)
3.2680 volts
(3e)
62 degree C
(20)
32 degree C
(1d)
29 degree C