Preparing The System For Operation After Installing A Pcie3 X8 Sas Raid Internal Adapter 6 Gb; Removing And Replacing The Pcie3 X8 Sas Raid Internal Adapter 6 Gb In The 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, Or 8284-22A; Preparing The System To Remove And Replace The Pcie3 X8 Sas Raid Internal Adapter 6 Gb - IBM PCIe3 x8 SAS RAID internal adapter 6 Gb Manual

Table of Contents

Advertisement

Preparing the system for operation after installing a PCIe3 x8 SAS
RAID internal adapter 6 Gb
Learn how to prepare the system for operation after installing a PCIe3 x8 SAS RAID internal adapter 6
Gb.
To prepare the system for operation, complete the following steps:
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is
connected to an unpainted metal surface. If not, do so now.
2. Replace the service access cover. For instructions, see "Installing the service access cover on a
5148-21L, 5148-22L, 8247-21L, 8247-22L, 8247-42L, 8284-21A, 8284-22A, 8286-41A, or 8286-42A system"
on page 50.
3. Remove the electrostatic discharge (ESD) wrist strap.
4. For a rack-mounted system, place the system into the operating position. For instructions, see
"Placing the rack-mounted system into the operating position" on page 58.
5. Reconnect the power cords to the system. For instructions, see "Connecting the power cords to the
system" on page 61.
6. Start the system for a nonconcurrent repair. For instructions, see "Starting the system or logical
partition" on page 30.
7. Verify the installed part.
v If you replaced the part because of a service action, verify the installed part. For instructions, see
Verifying a repair.
v If you installed the part for any other reason, verify the installed part. For instructions, see
"Verifying the installed part" on page 66.
Removing and replacing the PCIe3 x8 SAS RAID internal adapter 6 Gb
in the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A
Learn how to remove and replace a PCIe3 x8 SAS RAID internal adapter 6 Gb.
If your system is managed by the Hardware Management Console (HMC), use the HMC to repair a part
in the system. For instructions, see "Repairing a part by using the HMC" on page 65.
If you do not have an HMC, complete the following steps to prepare to remove a SAS RAID internal
adapter:

1. "Preparing the system to remove and replace the PCIe3 x8 SAS RAID internal adapter 6 Gb"

2. "Removing the PCIe3 x8 SAS RAID internal adapter 6 Gb from the 5148-21L, 5148-22L, 8247-21L,
8247-22L, 8284-21A, or 8284-22A" on page 12
3. "Replacing the PCIe3 x8 SAS RAID internal adapter 6 Gb in the 5148-21L, 5148-22L, 8247-21L,
8247-22L, 8284-21A, or 8284-22A" on page 14
4. "Preparing the system for operation after removing and replacing the PCIe3 x8 SAS RAID internal
adapter 6 Gb" on page 17
Preparing the system to remove and replace the PCIe3 x8 SAS RAID
internal adapter 6 Gb
Learn how to prepare the system to remove and replace the PCIe3 x8 SAS RAID internal adapter 6 Gb.
To prepare the system to remove and replace a SAS RAID internal adapter, complete the following steps:
1. If you are removing the PCIe3 x8 SAS RAID internal adapter 6 Gb as part of another service
procedure, go to step 3 on page 9.
8