Step Mount
Mounting the StructureScan transducer under the step not only protects the
transducer from hitting objects in the water, but does not cause any drag on your
boat when it is on plane.
1/8" Drill bit (Transom mount pilot holes)
To use Step Mount:
1.
Choose a transducer location.
2.
Route the transducer cable to the location where the LSS-1 will be
installed.
3.
Move the transducer bracket into the desired position and then use
a pencil to mark the pilot
holes through the slots in
the bracket.
4.
Drill the pilot holes.
5.
Apply a high-grade above-
or below-waterline sealant
to the pilot holes.
6.
Align the bracket slots over
the pilot holes and fasten
the bracket to the transom
using your drill and the
supplied screws.
7.
To make adjustments to
transducer position, loosen
the
screws
bracket up or down.
8.
Connect the transducer cable to the LSS-1 sonar port.
Step Mount Supplies (not included)
and
slide
Marine grade above- or below-
waterline sealant
Step
StructureScan transducer mounted
under the step.