9. CHECKING FUNCTIONAL MEMBERS
9-1 VOLTMETER
Check the voltmeter if
it
is turned on by applying
specific
i
Voltmeter cannot be checked with circuit tester
!
AC
because its resistance is too large.
I
i
i
Voltmeter
I
Fig.
9-1
9-2
AC RECEPTACLES
.
Using a "Dr. Robin" or a circuit tester, check continuity between the two terminals at the rear of the AC
receptacles while the receptacle is mounted on the control panel. When continuity
is found between the
output terminals of the receptacle with a wire connected across these terminals: the
AC receptacle is
normal. When the wire
is removed and no continuity
is found between these terminals, the receptacles
are also normal.
AC RECEPTACLE
\
F/c;. 9-2A
-