INDOOR UNIT INSTALLATION

4) Forming the Drain Hose and Refrigerant Piping

• Drain hose and drain cap are assembled as shown in figure 9 in the factory. To do right-side( ), right-botton( ) or right-back( ) piping in figure 3, draw
the drain hose to right-side piping direction.(It is not necessary to exchange the location of drain hose and drain cap.)
• Tie the refrigerant pipe, the drain hose, and the electrical connection cord together.
• Form the refrigerant piping in the required direction, and bind the drain hose and the electrical connection cord together with vinyl tape.
The drain hose should be at the bottom. ( Figure. 10 )
Figure 9
• For Left Piping, fit the pipes and the wiring into the recess at the back of the unit as shown in Figure 11.

5) Installing the Indoor Unit Body to the Wall Hang Bracket

• Pass the pipes through the wall sleeve and then hook the indoor unit body onto the top of the wall hang bracket. ( Figure. 12 )
• For Left Piping, hang the unit onto the top of the wall hang bracket and incline the unit using a tool such as a screw
-driver set between the middle area of body and bottom right of the wall hang bracket. Connecting the pipe can be done more easily if the unit is inclined.
• Snap the marking places of the body(A, B) onto the hole of the bracket.
26
Figure 10
Figure 11