Electrical - General Instructions
It is recommended that a licensed electrician install the power to your spa, in accordance with
the National Electric Code or any local electrical codes in effect at the time of installation.
The circuit breaker must be dedicated and cannot be shared with any other appliances. It
should be labeled and easily accessible to users. DO NOT USE EXTENSION OR PLUG-
TYPE CORDS OF ANY KIND. The use of a shut-off box near the spa is recommended.
Metal surfaces within 5 feet of the spa must be grounded to the spa.
A 120 Volt - 15 Amp GFI rated plug is furnished with the Cyprus Spa.
CAUTION: This spa will not work if more than one GFCI is used on the circuit. On 220 Volt applications,
Note: Your Cyprus Spa's Heater can be converted to 220 Volts. The Spa's pump will remain 120 Volts.
To convert spa from 120 volt
to 220 Volt remove white
jumper wire from J24 and
neutral block.
Next, move white wire from
J14 and connect it to J10.
Connections should be made using copper conductors only. The connecting wire and circuit breakers
or fuses must be sized to accommodate the total ampere load as specified on the equipment module
data label.
Strong Pools and Spas only makes electrical recommendations, always consult a certified electrician.
power supply must be hard wired into the power pack.
120V CYPRUS - SPECIAL EDITION
Electrical Connections:
L1
L2
Two Wire
& Ground
GRD
This change must be performed by a certified electrician.
Three Wire
& Ground
TERMINAL
BLOCK
220V CYPRUS
Electrical Connections:
TERMINAL
BLOCK
L1
L2
N
GRD
4
These wires go to
the PC Board
Control Circuit.
These wires go to
the PC Board
Control Circuit.