5-5. Finishing the Installation

After finishing insulating and taping over the tubing, use sealing
putty to seal off the hole in the wall to prevent rain and draft
from entering.
Apply putty here

6. BEFORE SWITCHING ON

Check if the filter is installed properly.
G
Check if the horizontal airflow direction louver works properly.
G
Type 45, 56, 73, 106
Air filters
Front panel
Vertical airflow direction louver
Horizontal airflow direction louver
7. HOW TO INSTALL TIMER REMOTE
CONTROLLER OR HIGH-SPEC WIRED
REMOTE CONTROLLER (OPTIONAL
PART)
NOTE
Refer to the Operating Instructions attached to the optional
Timer Remote Controller or optional High-Spec Wired Remote
Controller.
Tubing
Indicator
Receiver
8. PRECAUTIONS ON TEST RUN
Request that the customer be present when the test run is
G
performed. At this time, explain the operation manual and
have the customer perform the actual steps.
Check that the 220 – 240 V AC power is not connected to
G
the inter-unit control wiring connector terminal.
* If 220 – 240 V AC is accidentally applied, the indoor unit
control PCB fuse will blow in order to protect the PCB.
In this case, make the wiring correctly. Then reconnect the
connector to pins 2 and 3 from pins 1 and 2 on the 3P DIP
pin (EMG).
If the operation is not activated even if the short circuit pin
is reconnected, cut the jumper on the indoor unit PCB.
(Be sure to turn the power OFF before performing this
work.)
20
Jumper
(JP040)
EMG (CN044)
Short circuit pin
3
2
1
3P DIP pin (EMG)