Quick Start Guide
Relion® 620 series
13
1
Display
2
Self-supervision and
protection indicator LEDs
3
Programmable LEDs
4
Control Circuit Breaker or
disconnectors
5
Escape / Cancel
6
Navigation
7
Enter / Select
8
Authorization
9
Clear
10
Menu
11
Local / Remote
12
Help
13
Function buttons
2
4
Default view can be selected from e.g. single line diagram (SLD), measurements, events
Ready-LED steady: OK, Ready-LED flashing: Internal Relay Fault (IRF), Start-LED steady: protection started,
Start-LED flashing: protection function blocked, Trip-LED: protection operated
Can be programmed for alarming and indication as latched the signal. Flashing/steady features.
Press open/close and confirm by pressing enter. If there is more than one controllable object select the object
first with navigation buttons. Note: control has to be in Local mode.
Used for canceling actions and leaving setting mode without saving the values. Returns back to menu.
Left = go back, Right = go further, Up = scroll up, Down = scroll down. Up/down can also be used when selecting
controllable objects like breakers and switches in single line diagram.
Entering to parameter setting mode and confirming new values
If authorization is used you can log in or log out using this button
Clearing events and indications, see next page for further details
Switch views in between the main menu, single line diagram and measurements
Changes the control between Local/Remote
View help messages
Can be configured as control buttons
1
5
6
7
9
10
8
11
12
3

Advertisement

loading

Summary of Contents for ABB Relion 620 Series

  • Page 1 — Quick Start Guide Relion® 620 series Display Default view can be selected from e.g. single line diagram (SLD), measurements, events Self-supervision and Ready-LED steady: OK, Ready-LED flashing: Internal Relay Fault (IRF), Start-LED steady: protection started, protection indicator LEDs Start-LED flashing: protection function blocked, Trip-LED: protection operated Programmable LEDs Can be programmed for alarming and indication as latched the signal.
  • Page 2 These are described below: S = Parameters are being stored, ! = Warning and/or indication Complete customer documentation is available in the product V = Viewer, O = Operator, E = Engineer, A = Administrator pages that can be accessed through abb.com/relion.
  • Page 3 Q U I C K S TA R T G U I D E R E L I O N ® 6 2 0 S E R I E S — Most common function blocks The most common function blocks are listed below, please refer to the 620 series Technical Manual for the full list. The available function blocks varies depending on the selected IED and configuration used.
  • Page 4 With regard to purchase orders, illustrations contained therein. Any reproduction, disclosure to third the agreed particulars shall prevail. ABB does not accept any responsibility parties or utilization of its contents – in whole or in parts – is forbidden whatsoever for potential errors or possible lack of information in this without prior written consent of ABB.