6. Examine the Results
See Figure 4:
Manual limit selected (default): To give a PASS or FAIL grade to the image,
tap GRADE.
Test limit selected: To see an analysis of the defects, tap ANALYZE. The
tester uses the selected test limit to give scratches and defects a PASS
(green highlight) or FAIL (red highlight) grade.
If a defect is possibly a dirt particle, clean the endface and do the
inspection again. You must remove all loose particles because
they can move into the core when you make connections.
7. Save the Results
7-1 Tap SAVE.
7-2 If the Cable ID box shows the correct ID, tap SAVE.
To enter a cable ID, tap the Cable ID box on the SAVE RESULT screen, use the
keyboard to enter a name for the results, tap DONE, then tap SAVE.
The tester saves the results in the DEFAULT project, unless you selected a
different project.
Figure 4. Examples of FiberInspector Results Screens