– Select „Measured value block 68 - ash mass DPF" -arrow- on
screen and confirm with
– Follow instructions of vehicle diagnostic, testing and informa‐
tion system -VAS 5051B- or vehicle diagnostic and service
information system -VAS 5052 A- .
– Press
button -arrow- to display the ash mass measured
Read
values.
The ash mass is displayed in the result column -arrow-.
Note
If the limit value of 95 grams is reached the diesel particulate
filter must be renewed ⇒ Rep. gr. 26 .
If the indicated ash mass limit value is not reached, the vehicle
can be driven further 40,000 km.
The ash mass (saturation level) of the diesel particulate filter
must be read every 40,000 km.
– Follow instructions of vehicle diagnostic, testing and informa‐
tion system -VAS 5051B- or vehicle diagnostic and service
information system -VAS 5052 A- and end „Guided functions"
operating mode with
– Switch off ignition and then disconnect vehicle diagnostic,
testing and information system -VAS 5051B- or vehicle diag‐
nostic and service information system -VAS 5052 A- from
vehicle.
4.4
Battery: Check battery terminal clamps
for secure seating
♦ Specified torques: Battery

♦ Battery: Check battery terminal clamps for secure seating

⇒ page 48
.
♦ Battery terminal connections