55 gallon 200 liter drum size air-powered ram

Advertisement

Mounting the Pump (Model 223–634 Ram)
NOTE: Model 223–634 Ram is only for use with Check–
Mate 450 Pumps having a 222–790 Displace-
ment Pump. The Pump Selection Chart on page
3 lists the Check–Mate 450 Pumps which can be
mounted on this ram.
This installation requires Mounting Kit 222–776.
See Accessories on page 18.
1. Place the gasket (K) from Mounting Kit 222–776 on
the ram plate. See Fig 2. Lower the Check–Mate 450
Fig 2
INSTALLATION
L
M
RAM PLATE
pump onto the gasket and plate. Secure the pump's
intake flange to the plate with the screws (L) and lugs
(M) included in the mounting kit.
2. For Senator and Bulldog Check–Mate 450 Pumps
only: Position the mounting brackets (57) under the
base of the air motor. See the Typical Installation on
page 4. Attach the motor to the mounting brackets
with the screws (27) and washers (26) provided. The
mounting brackets (57) are not used with Monark
and President Check–Mate 450 Pumps.
CHECK–MATE 450 PUMP
INTAKE FLANGE
K