Vitotrans 353 (Freshwater Module); Overview Of Product Features; Intended Use Of Viessmann Cylinders - Viessmann Vitocell 300-H Technical Manual

Hide thumbs Also See for Vitocell 300-H:
Table of Contents

Advertisement

Product information

Vitotrans 353 (freshwater module)

Draw-off rate 25 l/min, 48 l/min, 68 l/min
Freshwater module for hygienic DHW heating in accordance with the
instantaneous water heater principle.
Available for wall mounting as types PBSA, PBMA and PBLA or as
types PZSA and PZMA for installation on the heating water buffer
cylinder Vitocell 100-E, Vitocell 120-E, Vitocell 140-E and
Vitocell 160-E.

2.2 Overview of product features

Cylinder
Nominal ca-
pacity in l
Type
Vitocell 100-H
CHA
130
Vitocell 300-H
EHA
160
Vitocell 100-V
CVA
160
CVAA
CVAA-A
Vitocell 100-V
CVWA
300
Vitocell 300-V
EVIA-A
160
EVIA-A+
Vitocell 100-W
CUGA
120
CUGA-A
Vitocell 100-L
CVLA
500
Vitocell 100-B
CVB
300
CVBB
Vitocell 100-U
CVUB
300
CVUC-A
Vitocell 300-B
EVBA-A
300
Vitocell 340-M
SVKA
400
SVKC
750
Vitocell 360-M
SVSB
750
All cylinders are supplied with thermal insulation. Cylinders with "-A"
(e.g. CUGA-A) or "-A+" (e.g. EVIA-A+) in their type designation are
additionally equipped with vacuum-insulated panels, enabling them
to achieve ErP energy efficiency class A or A+ respectively.

2.3 Intended use of Viessmann cylinders

The appliance is only intended to be installed and operated in sealed
unvented systems that comply with EN 12828 / DIN 1988, or solar
thermal systems that comply with EN 12977, with due attention paid
to the associated installation, service and operating instructions.
DHW cylinders are only designed to store and heat water of potable
water quality. Heating water buffer cylinders are only designed to
hold fill water of potable water quality. Only operate solar collectors
with the heat transfer medium approved by the manufacturer.
Intended use presupposes that a fixed installation in conjunction with
permissible, system-specific components has been carried out.
Commercial or industrial usage for a purpose other than heating the
building or DHW shall be deemed inappropriate.
DHW heating
(cont.)
Material
of
to Stain-
Enamel-
less
led
steel
200
X
500
X
950
X
500
X
500
X
150
X
950
X
950
X
300
X
500
X
400
X
950
X
950
X
Freshwater modules of the type for installation on the heating water
buffer cylinder include a DHW circulation pump and a diverter valve
for directed return stratification (also available for wall mounting as
an option).
All pumps are highly efficient.
With types PBMA (48 l/min) and PBLA (68 l/min), cascades with up
to 4 identical modules are possible.
Version
Steel
Horizon-
Vertical
(buffer)
tal
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Vertical cylinders with a nominal capacity of ≤ 300 l are encased in
foam, as are horizontal cylinders. Vertical cylinders with a nominal
capacity of > 300 l are supplied with separate thermal insulation.
Any usage beyond this must be approved by the manufacturer for
the individual case.
Incorrect usage or operation of the appliance (e.g. the appliance
being opened by the system user) is prohibited and results in an
exclusion of liability.
Incorrect usage also occurs if the components in the system are
modified from their intended use (e.g. through direct DHW heating in
the collector).
Adhere to statutory regulations, especially concerning the hygiene of
potable water.
Heat exchanger
Colour
Number
Sep.
Vitosilver
DHW
coil
1
X
1
X
1
X
1
X
1
X
1
X
2
X
2
X
2
X
1
X
X
1
X
X
1
X
X