2
Overview
General description
ABB/Jokab Safety adaptor units are used to adapt conventional safety sensors where the safety relies on e.g. one-
or two-channel static signals, OSSD outputs, or short circuit detection, to the dynamic safety circuit monitored by a
Vital safety module or Pluto safety-PLC.
Tina 10A, -B and -C are used to adapt Focus light beams and light curtains with OSSD outputs to the dynamic
safety circuit. This also enables complete external interconnections using cables with M12 connectors only, which
reduces the cabling to and connections in the apparatus enclosure.
All Tina 10 units have an 8-pole female M12 connector for easy connection to a Focus receiver and a 5-pole male
M12 connector for quick installation to the dynamic safety circuit. Tina 10B has an extra 5-pole female M12
connector that enables reset, a reset lamp and switching the Focus supply voltage ON/OFF. The Tina 10C also
has an extra 5-pole female M12 connector but the extra connector is instead used to connect a Focus transmitter
(for power supply instead of using an extra M12-3B).
The Tina 10A/B/C adaptor unit is intended for use in safety circuits in accordance with EN 60204-1.
Safety regulations
Warning!
Carefully read through this entire manual before using the device.
The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine
directive.
Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions,
improper installation or handling of the device can affect the safety of people and the plant.
For installation and prescribed use of the product, the special notes in the instructions must be carefully observed
and the technical standards relevant to the application must be considered.
In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the
product, any liability is excluded.
2TLC172145M0201, rev. A
5
www.abb.com/lowvoltage
2011-09-23