Technical Data - ABB Tina 10A Original Instructions Manual

Adaptor unit
Hide thumbs Also See for Tina 10A:
Table of Contents

Advertisement

6

Technical data

Manufacturer
Address
Article number/Ordering data
Power supply
Operating voltage
Total current consumption
Time delay t (in/out)
Voltage supply at normal operation (protection OK)
and 24 VDC supply voltage
General
Protection class
Ambient temperature
Humidity range
Housing material
Connector
Size
Weight
Colour
Safety / Harmonized Standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
EN 954-1
Certificates
2TLC172145M0201, rev. A
2011-09-23
ABB AB / JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Tina 10A: 2TLA020054R1200
Tina 10B: 2TLA020054R1300
Tina 10C: 2TLA020054R1600
24 VDC +20 %, -20 %
60 mA (70 mA with max information output)
Information output: Max 10 mA
t < 120 µs
Dynamic input: between 9 and 13 volt (RMS)
Dynamic output: between 9 and 13 volt (RMS)
Information output: ~ 23 VDC
IP67
Storage: -10...+55°C
Operation: -10...+55°C
35 to 85 % (with no icing or condensation)
PVC
Tina 10A: M12 8-pole female, M12 5-pole male
Tina 10B: M12 8-pole female, M12 5-pole female, M12 5-pole male
Tina 10C: M12 8-pole female, M12 5-pole female, M12 5-pole male
77 x 36 x 15 mm (L x W x H)
~40 g
Black
European Machinery Directive 2006/42/EC
EN ISO 12100-1:2003, EN ISO 12100-2:2003,
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008,
EN 62061:2005, EN 61496-1:2004 + A1:2008
-9
SIL3, PFH
: 4.50*10
d
SIL3
Performance level: Pl e, category 4
Category 4
TÜV Nord
10
www.abb.com/lowvoltage

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tina 10bTina 10c

Table of Contents