Clearances with Passive Heat Optional Heat Management System
Figure 10.19 shows the required clearances for appliance,
ceiling finishing material and framing members. Ensure
all clearances are maintained.
Good Faith Guidelines for TV Installations
Above a MEZZO-C Fireplace with Passive Heat Option
(Single-Sided Appliance Shown)
WARNING! Risk of Fire!
opening is greater than 3 inches. Secure wire mesh to top of framing.
ROOM CEILING
MEZZO36/36ST-C = 48 IN. MIN.
MEZZO48/48ST-C = 48 IN. MIN.
MEZZO60/60ST-C = 48 IN. MIN.
MEZZO72/72ST-C = 67-1/2 IN. MIN.
MEZZO36/36ST-C = 76-1/2 IN. MIN.
MEZZO48/48ST-C = 76-1/2 IN. MIN.
MEZZO60/60ST-C = 76-1/2 IN. MIN.
MEZZO72/72ST-C = 95 IN. MIN.
Measurement from top edge
of opening to bottom of
* Wire mesh required for front discharge or open top discharge passive heat installations with discharge
opening of 3 inches or greater.
Wire mesh recommended for front discharge or open top discharge passive heat installations with discharge opening
of less than three inches.
Figure 10.19 Clearances with Passive Heat Optional Heat Management System Installed
68
Heat & Glo • MEZZO36-C/ST-C, MEZZO48-C/ST-C, MEZZO60-C/ST-C, MEZZO72-C/ST-C Installation Manual • 2600-980 Rev. D • 9/19
Wire mesh required on bottom of discharge opening when discharge
1-1/2 IN. (2 X 4 FRAMING)
2 IN. MIN.
4 IN. MIN.
1/2 IN. X 1/2 IN.
WIRE MESH*
2 X 4 FRAMING
2 X 4 OR 2 X 6
FRAMING
TV
12 IN. MIN.
appliance = 24-1/2 IN.
CHASE CEILING (1/2 INCH WALL SHEATHING/FINISHING MATERIAL)
REQUIRED FOR FRONT AND SIDE DISCHARGE
CANNOT BE INSTALLED ON OPEN TOP DISCHARGE
WIRE MESH*
= PASSIVE HEAT
DISCHARGE OPENING
FIREPLACE
OPENING