Mounting and Installation
■Installation
When mounting the Auto switch to actuator it should be done with clamp for actuator.
"How to mount" depends on actuator type and tube I.D. Please refer the actuator catalogue.
When the Auto switch is mounted newly, please prepare the clamp for actuator after confirms that the
actuator built in magnet.
•Proper tightening torque
Use a watchmaker driver whose grip diameter is 5 to 6 mm when tightening the mounting screw.
M2.5 mount screw tightening torque range shall be 0.05 to 0.15 Nm (0.5 to 1.5 kgf•cm)
•Setting the detecting position
Set the actuator at the stroke end. Set the switch in the area to where the auto switch red lamp light.
(Detecting actuator end)
Based on A and B dimensions in the actuator catalogue, set the switch.
For actual installation works, perform adjustment with checking the operating conditions of the Auto switch.
Air grippers and rotary actuators have their own setting method. Follow their instructions.
-11-
No.D-※S-OMK0010-E