Certificates And Approvals; Dimension Drawings - Siemens Sitrans LH100 Compact Operating Instructions

Pressure transmitter for hydrostatic level
Hide thumbs Also See for Sitrans LH100:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
Auxiliary power U
H
Terminal voltage at transmitter
Current consumption
Reverse polarity protection
8.1

Certificates and approvals

Certificates and approvals
Drinking water
Explosion protection
● Intrinsic safety "i"
Marking
9

Dimension drawings

Pressure transmitter
Cable
sheath, 8.3 mm diameter (black, PE-
HD)
- (Green)
+ (Brown)
Figure 9-1
Pressure transmitter, dimensions in mm
Cable box
Fastening hole
Vent valve
SITRANS LH100 (7MF1572..) Transmitter for hydrostatic level
A5E32588610-02, 02/2014
10 V DC to 30 V DC
10 V DC to 33 V DC
< 20 mA
Yes
ACS, WRAS
II 1 G Ex ia IIC T4 Ga
Protective conductor connection/
Equipotential bonding
Vent pipe,
1 mm diameter (inside diameter)
Protective cover with 4 x 3 mm diameter hole (black, PPE)
Pg 9 cable gland,
cable diameter 4 to 8 mm
37