Daikin DCG Series Service Instructions Manual page 4

Commercial package units with r-410a refrigerant. 7.5 - 12.5 tons & accessories
Table of Contents

Advertisement

PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.
Brand
D
Daikin
Configurat i on
C
S
T
Application
C
Cooling
3
G
Gas Heat
3
H
Heat Pump
Nominal Cooling Capacity
036 3 Tons
102 8½ Tons
048 4 Tons
120 10 Tons
060 5 Tons
150 12½ tons
072 6 Tons
180 15 Tons
090 7½ Tons
240 20 Tons
Nominal Heating Capacity
Gas/Electric
A/C H/P Factory-Installed Electric Heat
045
45,000 BTU/h
XXX No Heat
090
90,000 BTU/h
010 10 kW
115 115,000 BTU/h
015 15 kW
140 140,000 BTU/h
016 15 kW
210 210,000 BTU/h
018 18 kW
350 350,000 BTU/h
020 20 kW
400 400,000 BTU/h
025 25 kW
Voltage
1
208-230/1/60
3
208-230/3/60
Supply Fan/Drive Type/Motor
B
Belt Drive (single speed)
D
Direct Drive (3-5 Tons)
Factory-Installed Options
A
B
DDC-BACnet protocol
F
DDC-BACnet protocol
H
Disconnect Switch (non-fused)
J
Disconnect Switch (non-fused)
M Disconnect Switch (non-fused); DDC-BACnet protocol
1
2
Please use part number DPE36722 / DPE36724 / DPE36727 if Power Exhaust is required.
3
4
D
C
G
090
1
2
3
4,5,6
300 25 Tons
030 30 kW
031 30 kW
045 45 kW
046 45 kW
060 60 kW
4
460/3/60
7
575/3/60
V Two-Speed Belt Drive (also designates 6-Ton
with two-stage compressor)
H
1
R
DDC-BACnet protocol;
1
;
Disconnect Switch (non-fused)
V
W
1
;
Disconnect Switch (non-fused)
X
210
3
B
*
*
7,8,9
10
11
12
13
1
;
2
2
*
A *
14
15 16
Revision Levels
Major & Minor
Factory-Installed Options
X
A
Non-powered convenience outlet
B
Powered convenience outlet
C
Low-ambient kit
D
Return air smoke detector
E
Supply air smoke detector
F
Non-powered convenience outlet;
Low-ambient kit
G
Non-powered convenience outlet;
Return air smoke detector
H
Non-powered convenience outlet;
Supply air smoke detector
J
Non-powered convenience outlet;
Return & Supply air smoke detectors
K
Non-powered convenience outlet;
Low-ambient kit; Supply air smoke detector
L
Non-powered convenience outlet;
Low-ambient kit
Return & Supply air smoke detectors
M Powered convenience outlet;
Low-ambient kit
N Powered convenience outlet;
Return air smoke detector
O Powered convenience outlet;
Return & Supply air smoke detectors
P
Powered convenience outlet;
Supply air smoke detector
Q Powered convenience outlet; Low-ambient
kit; Return air smoke detector
R
Powered convenience outlet; Low-ambient
kit; Supply air smoke detector
T
Powered convenience outlet; Low-ambient
kit; Return & Supply air smoke detectors
U Non-powered convenience outlet;
Low-ambient kit; Return air smoke detector
V
Low-ambient kit; Return air smoke detector
W Low-ambient kit; Supply air smoke detector
Y
Low-ambient kit; Return & Supply
air smoke detectors
Z
Return & Supply air smoke detectors
Factory-Installed Options
X
Standard Aluminized Heat Exchanger
S
Stainless-Steel Heat Exchanger
D Hinged Panels
K
Stainless-Steel Heat Exchanger;
Hinged Panels
B
Phase Monitor
J
Stainless Steel Heat Exchanger; Phase Monitor
M Hinged Panel; Phase Monitor
L
Stainless-Steel Heat Exchanger;
Hinged Panels; Phase Monitor