Mechanical Adjustment

Needle drop position

Set the stitch pattern to "
Select zigzag stitch "
needle hole in the needle plate should be at least 0.2 mm on either side. If not, adjust as follows:
1. Remove the face cover. (See page 4.)
2. Turn the power switch on and check the needle drop position.
3. If the needle drop is out of position, adjust it to propper position by turning the adjusting screw "
the needle is in the center of the needle hole when the straight stitch "
4. Check the needle drop position of the zigzag stitch "
4. Attach the face cover.
NOTE:
Check the hook timing after this adjustment.
". The standard needle drop position should be at center of the needle plate hole
", and set the stitch width at " 5.0 ". The clearance between the needle and the edge of the
w
" is selected.
" with the maximum width.
0.2 mm
or more
10
w
" so that
q
0.2 mm
or more
A=B
q
.

Hide quick links: