Oil boiler
Table of Contents

Advertisement

How to install

Choosing of the installation place
For the place to install the boiler, choose the place possible to do the accompanying
works, such as water supply works or electric works.
For the place to install, choose the place conformed to the installation standards
of the boiler and the construction act of the code of each city or municipality
Install the boiler in the place as wide as possible for the maintenance and the re
prevention.
Install the boiler in the place convenient for controlling and manipulation of the
temperature.
If there is no electric outlet in the proper position, do wiring by requesting to a
company designated by the electric power company.
Around the installation place, there must be no place which stores and treats the
combustibles and the in ammables.
There should be equipped drainage in the in stalling spot.
The diagram of the standard piping : Cistern tank install type
Open cistern tank
Never install any valve between
the boiler and cistern tank.
Install the pipe as above when circulation pump
install heating water inlet
Supply Water
Pipe
Drain
Install the condensate outlet hose for condensing model as above
Expansion Tank
Supply Water Pipe
Circulation Pump
Bypass Pipe
Expansion Tank
Water
Hot Water Inlet
Minimum 1.5m
Circulation Pump
Distributor
Hot Water Outlet
Distributor
Heating Water
Inlet
Condensate
Outlet
F.L
Drain
Roop water
tank
Expansion tank
Water
In casa of water inlet through
roof water tank
Boiler Back
Hot Water Outlet
Hot Water
Cold Water
Heating Coil
Fan Coil
Radiator
Water