Time zone selecting
Set the time difference from Greenwich Mean Time in
the area where this unit is installed. When you send an
E-mail, the senting date and time is adjusted according
to this setting.
Select the time zone where this unit is installed from the
drop-down list. Click Apply to update the Current date
time setting according to the selection.
Notes
• If the time zone selected on the Time zone selecting
menu is different from that set on the computer, the
time is adjusted using the time zone difference and set
on this unit.
• Due to the network properties, there may be a slight
difference between the actual time and the time set on
this unit.
Date time format
Select the format of date and time to be displayed on the
monitor image from the drop-down list.
You can select from among yyyy-mm-dd hh:mm:ss
(year-month-day hour:minute:second), mm-dd-yyyy
hh:mm:ss (month-day-year hour:minute:second), and
dd-mm-yyyy hh:mm:ss (day-month-year
hour:minute:second).
Click Apply to transfer the setting to this unit.
Synchronization with NTP server
Synchronizes this unit's time with that of the NTP
(Network Time Protocol) server.
Select On to activate the time synchronization, and Off
to deactivate it.
NTP server name
Type the host name or IP address of the NTP server, up
to 64 characters.
This setting is valid when the Synchronization with NTP
server menu is set to On.
Interval time
Select the interval at which you want to adjust this unit's
time referring to the NTP server' time, between 1 and 24
hours. The set interval is a guide, and does not indicate
the exact time.
This setting is valid when the Synchronization with NTP
server menu is set to On.
Note
The time adjusted by this function may be slightly in
error depending on the network environments between
this unit and the NTP server.

Initialization Section

Backup setting
Saves the setting data of this unit in a file.
Click Save, and follow the instructions on the browser to
specify the folder and save the setting data of this unit.
The file name preset at the factory is "snc-dp10.cfg."
Restore setting
Loads the stored setting data of this unit.
Click Browse and select the file in which the setting data
is stored. Then, click Apply, and this unit is adjusted
according to the loaded data and restarted.
Note
The IP address setting in the Wired LAN setting section
(see page 20) on the Network setting page cannot be set.
Reboot
Reboots this unit.
Click Reboot, and "The SNC-DP10 will be rebooted.
Are you sure?" appears. Click OK to reboot this unit.
Factory default
Resets this unit to the factory settings.
Click Factory default, and "All configuration
information will be initialized as factory setting. Are
you sure?" appears. Click OK to reset to the factory
settings.