Clear Spray Tip Clog - Graco T-Max 506 Operation - Repair - Parts

Texture sprayer
Hide thumbs Also See for T-Max 506:
Table of Contents

Advertisement

Clear Spray Tip Clog

To avoid tip clogs:
When the applicator is not in use for
extended periods of time, keep the tip
"wet" and perform Pressure Relief
Procedure, page 19.
Keep spray tip clean and free of material.
1.
Rotate spray tip to unclog position. Aim
applicator at floor and turn applicator
ON. When clog clears, turn applicator
OFF.
UNCLOG
ti11714a
ti11794a
3A6748B
Start Up - Airless
2.
Rotate spray tip back to spray position.
Turn applicator ON. Spray test pattern.
ti11715a
ti11793a
NOTE: When spraying, if the applicator is not
used for a significant period of time be sure to
clean the sprayer, or keep the gun "wet" by
placing in water or wrapping with a wet cloth.
This reduces the potential of the material
drying in the gun causing pack-out of the gun.