1-1 TECHNICAL SPECIFICATIONS

Power input
Cooling
(nominal)
Heating
3
Casing
Material
Dimensions
Unit
Weight
Unit
Outdoor Unit
Liquid (OD)
Gas
Discharge Gas
Indoor Units
Liquid (OD)
Gas
Sound absorbing thermal insulation material
Standard
Item
Accessories
Notes

1-2 ELECTRICAL SPECIFICATIONS

Power Supply
Phase
Frequency
Voltage
Voltage range
Minimum
Maximum
Total circuit
Minimum circuit amps (MCA)
Maximum Fuse Amps
Notes
2
• BS Units • BS UNITS • BSVQ100-250P8B
kW
kW
Height
mm
Width
mm
Depth
mm
kg
Type
Diameter
mm
Type
Diameter
mm
Type
Diameter
mm
Type
Diameter
mm
Type
Diameter
mm
In case of connection with a
20~50 type indoor unit, match
to the size of the field pipe
using the attached pipe.
Connection between the
attached pipe and the field pipe
Hz
V
V
V
A
A
Voltage range : units are suitable for use on electrical systems where voltage supplied to unit
®
• VRV
Systems • BS Units
BSVQ100PV18
BSVQ160PV18
0.005
0.005
0.005
0.005
Galvanised steel
207
388
326
14.0
Brazing connection
9.5
Brazing connection
15.9
Brazing connection
12.7
Brazing connection
9.5
Brazing connection
15.9
Foamed polyurethane, Frame resisting needle felt
Installation manual
Attached piping
Insulation pipe cover
Clamps
In case of connecting with
indoor unit capaicty index 150
or more and 160 or less, match
to the size of the field pipe
using the attached pipe.
Connection between the
must be brazed.
attached pipe and the field pipe
must be brazed.
BSVQ100PV18
BSVQ160PV18
50
220-240
-10%
+10%
0.1
15
terminal is not below or above listed range limits
Maximum allowable voltage range variation between phases is 2%
MCA / MFA : MCA = 1.25 x FLA
MFA is smaller than or equal to 4 x FLA
Next lower standard fuse rating minimum 15A
Select wire size based on MCA
Instead of a fuse, use a circuit breaker
BSVQ250PV18
0.005
0.005
207
207
388
388
326
326
14.0
15.0
9.5
9.5
15.9
22.2
12.7
19.1
9.5
9.5
15.9
22.2
In case of connecting with a
200 type indoor unit or capacity
index more than 160 and less
than 200, match to the size of
the field pipe using the
attached pipe. Connection
between the attached pipe and
the field pipe must be brazed.
BSVQ250PV18
1~
50
50
0.1
0.1
15
15