™ APPLICATION GUIDE Applications Include: Radiant Heating Snowmelt Systems Solar Panel Input Wood Boilers Pool & Spa Heating Twin Coil Input for Commercial This booklet is not to be used as an installation manual. Detailed instructions are available at www.amtrol.com...
General Overview The Premier DC Series is a multipurpose indirect-fired water heater suitable for many uses. ™ 1. An indirect-fired heater with the top coil extracting heat for radiant or snowmelt systems. Acts as a combination buffer tank/indirect water heater. 2.
Product & Benefits The Dual Coil reduces equipment costs and installation time while saving space by combining multiple hydronic system components into one unit. Figure 1 shows how boiler cycling is reduced in radiant heating applications to increase efficiency. Figure 1 Radiant Zone with Domestic Water Controlling Supply Temperature By combining two high capacity heat exchangers in a single unit, the domestic water temperature can provide reliable control of radiant supply temperatures.
Page 4
Product & Benefits (Con’t) Commercial applications require rapid recovery to meet high demands. These sites also have large boilers to accommodate the building(s) heating load. When both coils are utilized to heat domestic water, Premier DC Series ™ have a heat transfer capability far in excess of traditional single-coil and tank-in-tank indirects. The resulting performance can allow competitive bids by using fewer heaters than the competition (Figure 2).
Page 5
Figure 3 Dual Coil Design Unique exchanger placement and ease of service are two major benefits of the Premier DC Series. Amtrol ™ ® is the only company utilizing a tank design that allows two removable heat exchangers to be arranged at opposite ends of the tank.
Page 6
Radiant and Snowmelt Applications 1. Determine the heat load for the application 2. Determine the supply temperature and flow for your system 3. Using the charts below, determine what domestic temperature and top coil flow combination will satisfy the space heat demand. 4.
Page 7
Commercial Use as Indirect Heater With both coils powered, the DC Series models have first-hour ratings up to 637 gallons at a 90°F domestic temperature rise. See the following charts for sizing: APARTMENT SIZING Model DC-80 PUMP SELECTION BOILER SELECTION Coil Flow (GPM) FT/Head MBH Available for DHW...
Installation The following diagrams depict general piping schemes for various applications. These diagrams are for reference only and should not be used as a detailed piping schematic. 1. Radiant with domestic temp controlling supply temp. Simple and cost-effective Differential controlled to with 15°F with heating load only 2.
Page 9
Installation (Con’t) Radiant Zone with Variable Speed Pump Input with Dual Boilers (Wood Boiler Shown) *Do not circulate when boiler is cold.
Page 10
Installation (Con’t) Dual Input with Solar Collectors Both Coils as Input (Reverse Return Piping) -10-...