Specifications - Sony TA-DA9000ES Operating Instructions Manual

Sony multi-channel integrated amplifier operating instructions ta-da9000es
Hide thumbs Also See for TA-DA9000ES:
Table of Contents

Advertisement

PROTECTOR/CHECK CODE 11
Irregular current is output from the speakers. Turn
off the amplifier, check the speaker connection and
turn on the power again.
PROTECTOR/CHECK CODE 12
The amplifier section is overheated. Check that the
ventilation hole is not covered. Turn off the
amplifier, leave the amplifier for a while and turn on
the power again.
PROTECTOR/CHECK CODE 13
The power section is overheated. Check that the
ventilation hole is not covered. Turn off the
amplifier, leave the amplifier for a while and turn on
the power again.
PROTECTOR/CHECK CODE 21
Turn off the amplifier and consult your nearest Sony
dealer.
PROHIBITED/CHECK CODE 71
The amplifier cannot output the sound due to the
copyright protection.
UNKNOWN SIGNAL/CHECK CODE 72
The amplifier is not compatible with the format of
the input signal.
Reference sections for clearing
the memory
To clear
All memorized settings
Customized sound fields

Specifications

Amplifier section
POWER OUTPUT
Rated Power Output at Stereo Mode
(8 ohms, 20 Hz – 20 kHz, THD 0.15%)
(4 ohms, 20 Hz – 20 kHz, THD 0.15%)
Reference Power Output
(8 ohms, 1 kHz, THD 0.09%)
(4 ohms, 1 kHz, THD 0.09%)
Actual Rated Maximum Output at Stereo Mode
(8 ohms, JEITA)
(4 ohms, JEITA)
Actual Rated Maximum Output at Surround Mode
(8 ohms, JEITA)
(4 ohms, JEITA)
See
page 17
page 33
1) Depending on the sound field settings and the
source, there may be no sound output.
2) Measured under the following conditions:
Area code
CEL
TW
KR
Frequency response
PHONO
Power Amp Block
Inputs (Analog)
PHONO
1)
200 W + 200 W
220 W + 220 W
2)
FRONT
: 200 W + 200 W
2)
CENTER
: 200 W
2)
SURR
: 200 W + 200 W
2)
SURR BACK
: 200 W + 200 W
2)
FRONT
: 220 W + 220 W
2)
CENTER
: 220 W
2)
SURR
: 220 W + 220 W
2)
SURR BACK
: 220 W + 220 W
1)
260 W + 260 W
320 W + 320 W
2)
FRONT
: 260 W + 260 W
2)
CENTER
: 260 W
2)
SURR
: 260 W + 260 W
2)
SURR BACK
: 260 W + 260 W
2)
FRONT
: 320 W + 320 W
2)
CENTER
: 320 W
2)
SURR
: 320 W + 320 W
2)
SURR BACK
: 320 W + 320 W
Power requirements
230 V AC, 50/60 Hz
110 V AC, 60 Hz
230 V AC, 60 Hz
RIAA equalization curve
±0.5 dB
10 Hz – 50 kHz
± 3 dB (8 ohms)
Sensitivity: 3.5 mV
Impedance: 50 kilohms
4)
3)
S/N
: 90 dB (A, 40 mV