Power outage
In case of a power outage, the device ceases to operate. After power is restored the device
undergoes 300 seconds of protection mode and then automatically returns to the mode before the
power outage. In case of a power outage, the controller retains all the settings that were set before
the outage.
NOTE
In case of a power outage longer than 2 hours air-water models with a water connection, water
has to be drained out from the connecting pipes between the external and the internal devices.
Operate in accordance with the specifications as described in the installation manual.
Display of the state of the device
After activating the power supply, the device displays current state of the device on the display
according to the operating mode and the values of basic parameters of the heating/cooling system of
the building.
Standby................................
Heating
Return
DHW
READING ON THE DISPLAY
Standby
Heating
35.5 °C
Return
32.3 °C
DHW
49.0 °C
T outside
7 °C
TD60 after 12 days
2016/02/10 12:24 TUESDAY Current time and day of the week.
Keys
35.5°C
down the basic display.
32.3°C
49.0°C
Current condition of operation.
Set or calculated temperature of heating (only in winter mode).
Current temperature of the return.
Current temperature of DHW.
Current outside temperature.
Time left until the start of DHW thermal desinfection (i.e. next
thermal desinfection will begin in 12 days). Setting of DHW
thermal desinfection is controlled by changing the parameters TD,
TD every and Start at described in section 6 of the basic menu
DHW.
TERMOTRONIC controller
and
allow scrolling up and
DESCRIPTION
Owner's Manual 13