IBM Power System S821LC Installing page 110

Hide thumbs Also See for Power System S821LC:
Table of Contents

Advertisement

About this task
If a single power supply failed, it can be replaced while the system is running.
Procedure
1. Attach the electrostatic discharge (ESD) wrist strap.
Attention:
v Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack, or to
an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging
your hardware.
v When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap is
used for static control. It does not increase or decrease your risk of receiving electric shock when
using or working on electrical equipment.
v If you do not have an ESD wrist strap, just prior to removing the product from ESD packaging and
installing or replacing hardware, touch an unpainted metal surface of the system for a minimum of
5 seconds.
2. Label and remove the power cord from the power supply to remove. For instructions, see
"Disconnecting the power cords from an 8001-12C, 8001-22C, 8005-12N, or 8005-22N system" on page
100.
3. Remove the power supply from the system.
a. To unseat the power supply from its position in the system, push the locking-tab to the left as
shown in Figure 55.
b. Grasp the power supply handle with one hand, and pull the power supply partially out of the
system.
c. Place your other hand underneath the power supply and pull the power supply out of the system
and place it on an ESD mat.
Figure 55. Removing a power supply from the system
94
Power Systems: Installing the IBM Power System S821LC (8001-12C)